8 Installation, removal
8.1 Dangers during installation
8 Installation, removal
8.1 Dangers during installation
The following safety instructions must be observed strictly:
o
Have all work carried out only by authorized qualified personnel.
o
Before installation ensure that the operating limits, NPSH values and ambient conditions are ob-
served.
o
Observe the tightening torques
Ä
o
Ensure that all the components can be accessed and that maintenance work can be carried out
easily.
8.2 Dangers during removal
The following safety instructions must be observed strictly:
o
Have all work carried out only by authorized qualified personnel.
o
Before beginning work, let the pump unit cool down to the ambient temperature.
o
Collect any discharging pumped liquid safely and dispose of it in an environmentally compatible
manner in accordance with the applicable local regulations.
o
Ensure that the collection tank for discharging pumped liquids is sufficiently large.
8.3 Mounting the pump station
The pump station is operated in a vertical installation position.
Notice
Soiling in the pipe system impairs the service life of the pump station. If the pipe system is flushed us-
ing the pump station during the initial commissioning, an additional commissioning filter has to be in-
stalled temporarily before the pump station. Alternatively the strainers supplied as standard can be re-
placed during commissioning by fine-meshed commissioning strainers.
Personnel qualification:
o
Transport personnel
o
Fitter
Personal protective equipment:
o
Work clothing
o
Protective gloves
o
Safety boots
Aids:
o
Mobile crane, forklift, hoisting equipment
WARNING
Risk of injury and damage to equipment through falling and toppling parts.
► Only fasten the pump station on a stable bearing underground.
► Ensure that fastening elements and pipings are fastened sufficiently.
ATTENTION
Damage to device through impurity in the pipe system.
► During welding work attach protective covers in front of the connecting flanges.
► Ensure when welding that welding beads and abrasive dust cannot get into the pipe system and
the pump station.
► Ensure that a commissioning filter is installed when the pipe system is flushed and cleaned using
the pump.