15 Accessories
15.1 Heating
15 Accessories
15.1 Heating
15.1.1
Possible types of heating
The pump can optionally be equipped with a heating system. The manufacturer recommends a heating
system at high-viscosity pumped liquids that do not flow sufficiently if not heated. A flowability that lies
too low can result in excessive power draw or to cavitation or sealing problems.
Possible types of heating:
o
Fluid heating system
15.1.2
Fluid heating system
483
1
1
Fig. 15: Fluid heating system
483
Heating cover
1
Pipe connection
The fluid heating system consists of a heating cover
483
, attached additionally to the end cover,
through which a heating liquid (for example vapour, thermal oil) flows.
Scope of delivery:
Size 15 – 3550
1 heating cover
8 socket screws
Tab. 12: Scope of delivery of the fluid heating system
Operating data
Parameter
Unit
Value
Max. pressure
[bar]
18
Max. liquid temperature
[°C]
220
Tab. 13: Operating data fluid heating system
Dimensions and steam amount
The following table shows the dimensions of the connections of the fluid heating system, depending on
the outer housing as well as the required steam amount for a temperature increase of 50 °C in a heat-
ing-up period of 1 h.