36
OIE 12en Edition 2019-02
Operating Instructions
Menu 2: General settings
M
e
n
u
d
e
s
c
ri
p
ti
o
n
1.08 Flow direction change Volumeter A
On this page the number of flow direction
changes of Volumeter A since the last reset is
displayed.
Prerequisite: In menu 2.13 the pulse inputs
function is set to "Encoder", see "2.13 Function
pulse inputs", page 38. Resetting of the value
functions analog to menu item 1.02.
Note
: The counter can be increased in case of a
voltage breakdown. We therefore recommend
resetting the counter before beginning
measuring.
1.09 Flow direction change Volumeter B
Description analog to menu item 1.08.
1.10 Reset bypass and
collective error message
After the cause for the activation of the collective
error message and of the bypass valve has been
eliminated, this function is used for resetting.
1.11 Setting display brightness
The brightness of the display is adjusted on this
page.
1.12 Setting display contrast
The contrast of the display is adjusted on this
page.
1.13 Setting select language
The language is selected on this page. The page
can be called up via the shortcut, see "1.13
Setting select language", page 34.
Menu 2: General settings
Menu 2 allows general adjustments in
accordance with the requirements of the
measuring task. All the settings can only be
changed after the password has been entered.
2.01 Enable password
Factory settings:
□
Password: "1000"
□
Password protection active (setting "Yes")
Deactivate password protection:
1. Press SET.
The password prompt is displayed.
2. Enter the password using the arrow keys, see
"General operating steps", page 29.
3. Press SET.
The password protection is deactivated: It is
possible to change the setting.
The password protection is reactivated
automatically after approx. 30 minutes.
If the password is not active, "No" is shown in the
display. The password can be activated at any
time again by pressing the SET and ARROW UP
or ARROW DOWN keys. This prevents
unwanted changes by third parties.
1.08 Display
Direction change
Volumeter A:
0
1.10 Display
Reset bypass and
coll. error message:
No
1.11 Setting
Display
Brightness:
100 %
1.12 Setting
Display
Contrast:
50 %
Setting
Meaning
Yes
□
Password protection is active
□
No changes possible
No
□
Password protection is not
active
□
Changes are possible
1.13 Setting
Select
Language:
English
2.01 Setting
Enable
Password:
Yes