Kozy-World GFNC2829 Скачать руководство пользователя страница 1

1

V E N T - F R E E   G A S
FIREPLACE SYSTEM

    WARNING: 

 If  the  information  in this

manual  is  not  followed  exactly, a  f ire  or
ex pl osion  m ay  r esul t causing  property
damage,  personal injury,  or  loss  of  life.

*Aftermarket: Completion  of  sale, not  for  purpose  of  resale,
from  the  manufacturer.

Do  not  store  or  use  gasoline  or  other  flammable
vapors  and  liquids  in  the  vicinity  of  this  or  any
other  appliance.

WHAT  TO  DO  IF  YOU  SMELL  GAS

Do  not  try  to  light  any  appliance.

Do   not   touch   any   electrical   switch;  do  not

       use  any  phone  in   your  building.

Immediately   call   your  gas  supplier  from  a

       neighbor

s   phone.   Follow   the   gas   supplier

s

       instructions.

If   you   cannot  reach  your  gas  supplier, call

       the  fire  department.
Installation  and  service  must  be  performed  by  a
qu alified   installer,  service   ag ency,  or    th e   g as
supplier.

        WARN ING:    

Im prop er      installatio n,  adjustmen t,

alteration, service or  maintenance can  cause  injury  or
property  damage. Refer  to  this  manual  for  correct  in-
stallation  and operational  procedures.  For  assistance
or  additional  information  consult  a  qualified
installer,  service  agency,  or  gas  supplier.

This  appliance  may  be  installed  in  an  aftermarket*,
permanently  located, manufactured (mobile) home,
where  not  prohibited  by  local  codes.
This appliance  is  only  for  use  with  the  type  of  gas
indicated  on  the  rating  plate. This appliance  is  not
convertible  for  use  with  other  gases.

World-Marketing of American,Inc.
P.O.Box 192,Rt.22 West
MillCreek,PA 17060

KOZY-WORLD PHONE NUMBER:(814)643-1775

      http://www.worldmkting.com

Kozy-World

R

Safety Information  Warnings.................................2

Air  for  Combustion and  Ventilation......................4

Installation................................................................6

Operating heater.....................................................11

Cleaning&Maintenance........................................12

Trouble Shooting...................................................13

Specifications.........................................................15

Replacement Parts List .......................................16

Logs installation  instruction.................................20

Installer: Please leave these instructions with the
   consumer.

Consumer: Please retain these instructions for
future use.

WATER  VAPOR: A BY-PRODUCT  OF  UNVENTED
ROOM HEATERS

Water vapor  is a by-product of gas combustion. An
unvented room heater produces approximately one(1)
ounce (30ml) of water for every 1,000 BTU

s(.3KW

s) of

gas input per hour. Refer to page 3.

    WARNING:  

 This  is  an  unvented gas-fired

heater.  It  uses  air  (oxygen)f r o m     t h e     r o o m
in     w h ic h     it     is  installed.  Provisions  for  ad-
equate combustion  and  ventilation  air  must b e
p r o vi d e d .     R e f e r     t o     A i r     F o r  Combustion
and  Ventilation section on page  4  of  this  manual.

               

Table of Contents

GFNC2829

GFPC2830

KW-BL035-03T-0606

Содержание GFNC2829

Страница 1: ...may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate T...

Страница 2: ...ified service person Note During initial operation slight smoking could occur due to log curing and heater burning manufacturing residues 9 To prevent the creation of soot follow the instructions in C...

Страница 3: ...In most applications the water vapor enhances the low humidity atmosphere experienced during cold weather The following steps will help insure that water vapor does not become a problem 1 Be sure the...

Страница 4: ...ON Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any a...

Страница 5: ...room unconfined Figure 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr WARNING If the area in which the heater may be o...

Страница 6: ...e aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in ro...

Страница 7: ...wells This gas is commonly known as wellhead gas CAUTION Only use a new black iron or steel pipe Internally tinned copper tubing may be used in certain areas Check you local codes Use pipe of 1 2 dia...

Страница 8: ...heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Pressure Testing Heater Gas Connections 1 Open equipment shutoff valve see Figure 8 Figure 9 Checking Gas Joints C...

Страница 9: ...anel Draw the four strand cable backward so as to expose the three black green white lines on the four strand cable at the back of rear panel Be sure not to drop the temperature controlled wire off th...

Страница 10: ...1 0 Installing Blower Accessory Blower Accessory Model 20 6028 Picture 7 Routing Power Cord Picture 8 Mouting Blower Picture 6 Attaching Bracket To Blower...

Страница 11: ...in C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it Call a qualified service technician or gas supplier...

Страница 12: ...ng page 13 BURNER FLAME PATTERN Figure 15 Correct Flame Pattern with Control Knob Set to High Flame Figure 16 Incorrect Flame Pattern with Control Knob Set to High Flame Figure 17 Injector Holder On O...

Страница 13: ...HOOTING When ignitor button is pressed in there is a spark at ODS pilot but no ignition OBSERVED PROBLEM POSSIBLE CAUSE REMEDY 1 Gas supply turned off or equipment shutoff valve closed 2 Control knob...

Страница 14: ...2 or replace burner injector 2 Have qualified service technician check inlet pressure 3 Reconnect lead Delayed ignition burner 1 Manifold pressure is too low 2 Burner parts or injector orifice clogged...

Страница 15: ...irements Page 4 POSSIBLE CAUSE 1 Heater is burning vapors from paint hair spray glues etc See IMPOR TANT statement at beginning of troubleshooting 2 Gas leak See WARNING Statement at beginning of trou...

Страница 16: ...or referral information You can also write to the address listed on the front page of this manual EQUIPMENT SHUTOFF VALVE Equipment shutoff valve with 1 8 NPT tap This part is not currently avail able...

Страница 17: ...1 7 ILLUSTRATED PARTS BREAKDOWN GFNC2829 GFPC2830 12 A 12 B 12 C 12 D 12 E...

Страница 18: ...r LP 1 4 BL023 01 Injector NG 1 BL024 01 Injector LP 1 5 BB32000 Outlet Tube Assembly 1 6 NRV81F1 3 Regulator RV81FI3 NG 1 NRV81F1 8 Regulator RV81FI8 LP 1 7 BB31000 Inlet Tube Assembly 1 8 BL015 01 T...

Страница 19: ...1 9 ILLUSTRATED PARTS BREAKDOWN GFNC2829 GFPC2830...

Страница 20: ...1 1 4 UB028 02 Base 1 5 BL016 01 Blower Mount Panel 1 6 SL005 01 Blower Bracket 2 7 BL017 01 Body Brass Trim 1 8 BL012 01 Body 1 9 BL007 01 Firebox Floor 1 10 BL015 01 Thermostat Valve Bracket 1 11 B...

Страница 21: ...own STEP 3 Install log 3 onto the two slots in front bracket as shown FIG 3 FIG 4 STEP 4 Insert the recessed hole on the bottom of log 4 onto the pin on log 1 Place the front part of log 4 on the flat...