Kozy-World GFN4035R Скачать руководство пользователя страница 1

1

  FULL SIZE VENT-FREE
      FIREPLACE

OWNER

S OPERATION AND INSTALLATION MANUAL

  WARNING:

 If the information in this

manual is not followed exactly, a  f i re  o r
exp l o si o n   may  resu l t  causing property
damage, personal injury, or loss of life.

    

 WARNING: 

 This is an unvented gas-fired

fireplace. It uses air (oxygen) f ro m t h e ro o m i n
w h ich  i t  i s installed. Provisions for adequate
combu st io n  and   ven ti lati o n  ai r  mu st   b e
p rovi d ed .  Ref er t o  Ai r Fo r Combustion and
Ventilation section on page 5 of this manual.

Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not

use any phone in your building.

Immediately call your gas supplier from a

neighbor

s phone. Follow the gas supplier

s

instructions.

If you cannot reach your gas supplier, call

the fire department. Installation and service
must be performed by a qualified installer,
service agency, or local gas supplier.

GFN4035R

GFP4036R

GFN4037R

GFP4038R

  WA R N I N G :     I m p r o p e r   i n s t a l l a t i o n ,

adjustment, alteration, service or maintenance
can cause injury or property damage. Refer to this
manual for correct installation and operational
pro cedures.  F or  assist ance  or  addi tion al
information, consult a qualified installer, service
agency, or local gas supplier.

This appliance may be installed in an aftermarket*,
permanently  located,  manufactured  (mobile)
home, where not prohibited by local codes.

This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale,
from the manufacturer.

Installer: Please leave these instructions with

the consumer.

Consumer: Please retain these instructions for

future use.

WATER VAPOR: A BY-PRODUCT OF UNENTED ROOM
HEATERS
Water vapor is a by-product of gas combustion. An unvented
room heater produces approximately one(1) ounce (30ml)
of water for every 1,000 BTU

s(.3KW

s) of gas input per

hour. Refer to page 4.

Kozy-World

R

World Marketing of  America, Inc.

P. O. Box 192, Rt.. 22 West

Mill Creek, PA 17060

KOZY WORLD PHONE NUMBER :(814)643-1775

http://www.worldmkting.com

KW-HL059-03RHW-0505

Содержание GFN4035R

Страница 1: ...N4035R GFP4036R GFN4037R GFP4038R WAR N I N G I m p r o p e r i n s t a l l a t i o n adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct...

Страница 2: ...roduct Identification 4 Air for Combustion and Ventilation 5 Installation 7 Operating fireplace 10 Cleaning Maintenance 13 Trouble Shooting 15 Specifications 16 Replacement 17 Parts List 18 Installing...

Страница 3: ...plier call the fire department 4 This fireplace shall not be installed in a bedroom or bathroom 5 Do not use this fireplace as a wood burn ing fireplace Use only the logs provided with the fireplace 6...

Страница 4: ...the fireplace if there is not enough fresh air PRODUCT IDENTIFICATION Figure 1 FULL SIZE VENT FREE FIREPLACE WATER VAPOR A BY PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by product of gas combu...

Страница 5: ...ining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining...

Страница 6: ...ation Air From Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr WARNING If the area in which the fireplace may be operated is smaller than that...

Страница 7: ...ce where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls CHECK GAS TYPE Use only the type of gas indicated on the plate...

Страница 8: ...7 IMPORTANT Install equipment shutoff valve in an accessible location The equipment shutoff valve is for turning on or shutting off the gas to the appliance Apply pipe joint sealant lightly to threads...

Страница 9: ...iquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect fireplace and equipment shutoff valve to gas supply Check reconnected fittings for leaks Pressure...

Страница 10: ...r explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any...

Страница 11: ...any air If you smell gas STOP Please check the gas connection There are three selections AUTO MAN and OFF a auto select of main burner Press BURNER button the flame is on AUTO select Press or to set...

Страница 12: ...uld be depressed for about thirty 30 seconds This will allow air to bleed from the gas system 7 With control knob pressed in push down and release the ignitor button This will light pilot If needed ke...

Страница 13: ...fore cleaning DISCONNECTWIRING ORCONTROL MODULE 1 Remove four screws from the rear con trol panel take out thermostat sensing bulb from the clip then disconnect the wires to free to control module fro...

Страница 14: ...lace clean Inspect these areas of fireplace before each use Have fireplace inspected yearly by a qualified service person H e a t e r m a y n e e d m o r e f r e q u e n t c l e a n i n g d u e t o ex...

Страница 15: ...service and repair fireplace CAUTION Never use awire needle or similarobject to clean ODS pilot This can damage ODS pilot unit When pressing the button of ignitor button is pressed there is spark at O...

Страница 16: ...page 13 2 Replace gas regulator Slight smoke or odor during initial op e r a t i o n 1 Residues from manufacturing pro cesses 2 Not enough air 3 Gas regulator defective 1 Problem will stop after a fe...

Страница 17: ...arranty card l Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product or Parts Central If they can t supply original re...

Страница 18: ...e Assembly 1 1 11 NRV82FB 4 Regulator NG 1 12 NRV82FB 9 Regulator LP 1 13 NV2020 22 Control Valve Assembly 1 1 14 MCL104 01 Normal Open Switch Bracket 1 1 15 MCL099 01 Normal Open Switch 1 1 16 MB1600...

Страница 19: ...1 1 11 HL015 01 Lower Panel 1 1 1 1 12 HL027 01 Door 1 1 1 1 13 HB11 03 Reflector Assembly 1 1 1 1 14 HL011 01 Left Inner Column 1 1 1 1 HL011 02 Right Inner Column 1 1 1 1 15 HL006 01 Upper Decorati...

Страница 20: ...20 ILLUSTRATED PARTS BREAKDOWN GFN4035R GFP4036R GFN4037R GFP4038R...

Страница 21: ...e 6 l Fasten decorations logs 4 onto the correspondent angle iron in front of firebox See figure 7 l Insert the pinhole in the upper part of log 4 into the pin on the left side of log 1 Place the lowe...

Отзывы: