Kozy-World GFN2815R Скачать руководство пользователя страница 1

1

V E N T - F R E E   G A S
FIREPLACE SYSTEM

 

WARNING

 

If  the  information

i n   this    manual    is    not    followed
exactly, a  f ire  o r  exp lo si on    may
r e s u l t  causing    property    damage,
personal injury,  or  loss  of  life.

*Aftermarket: Completion  of  sale, not  for  purpose  of
resale,  from  the  manufacturer.

Do  not  store  or  use  gasoline  or  other  flam-
mable vapors  and  liquids  in  the  vicinity  of  this
or  any
other  appliance.

WHAT  TO  DO  IF  YOU  SMELL  GAS

Do  not  try  to  light  any  appliance.

Do   not   touch   any   electrical   switch;  do

not use  any  phone  in   your  building.

l  

Immediately    call    your  gas  supplier

from  a neighbor

s   phone.   Follow   the   gas

supplier

s instructions.

If   you   cannot  reach  your  gas  supplier,

call the  fire  department.
Installation  and  service  must  be  performed
by  a qualified  installer, service  agency, or
the  gas supplier.

     

WA R N I N G

:     I m p r o p e r       i n s t a l l a t i o n ,

a d jus tme n t,  a lte ra tio n ,  s e rv ic e   o r  ma in te na n c e
can  cause  injury  or  property  damage. Refer  to  this
manual   for  correct   installation  and op eratio na l
procedures.  For  assistance  or  additional  infor-
mation  consult  a  qualified installer,  service  agency,
or  gas  supplier.

This  appliance  may  be  installed  in  an
aftermarket*,  permanently  located, manu-
factured (mobile) home, where  not  pro-
hibited  by  local  codes.
This appliance  is  only  for  use  with  the
type  of  gas  indicated  on  the  rating  plate.
This appliance  is  not  convertible  for  use
with  other  gases.

Installer: Please leave these instructions with the
consumer.

Consumer: Please retain these instructions for
future use.

WATER VAPOR: A BY-PRODUCT OF UNVENTED
ROOM HEATERS

Water vapor is a by-product of gas combustion.
An unvented room heater produces approximately
one (1) ounce (30ml) of water for every 1,000 BTU

s

(.3KW

s) of gas input per hour. Refer to page 4.

  WARNING: 

 

 

This  is  an  unvented gas-fired

heater.  It  uses  air  (oxygen) f r o m     t h e     r o o m     i n
w h i c h     i t     i s  installed.  Provisions  for  adequate
combustion  and  ventilation  air  must b e   p ro v id e d .
R e f e r     t o     A i r     F o r  Combustion  and  Ventilation
section on page  5  of  this  manual.

OWNER

S OPERATION AND INSTALLATION MANUAL

GFN2815R

GFP2816R

GFN2817R

GFP2818R

GFN2819R

GFP2820R

Kozy-World

R

World Marketing of  America, Inc.

P. O. Box 192, Rt.. 22 West

Mill Creek, PA 17060

KOZY WORLD PHONE NUMBER :(814)643-1775

http://www.worldmkting.com

KW-BL035-03RHW-0505

Содержание GFN2815R

Страница 1: ...ditional infor mation consult a qualified installer service agency or gas supplier This appliance may be installed in an aftermarket permanently located manu factured mobile home where not pro hibited...

Страница 2: ...ir for Combustion and Ventilation 5 Installation 7 Operating heater 10 Cleaning Maintenance 13 Trouble Shooting 15 Specifications 16 Replacement 17 Parts List 18 Logs installation instruction 22 Mante...

Страница 3: ...If you smell gas Shut off gas supply l Do not try to light any appliance l Do not touch any electrical switch do not use any phone in your building l Immediately call your gas supplier from a neighbor...

Страница 4: ...orm dealer where you bought stove PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing ODS safety shutoff system The ODS pilot is a re quired feature for vent free ro...

Страница 5: ...TION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any...

Страница 6: ...m unconfined Figure 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr WARNING If the area in which the heater may be oper...

Страница 7: ...mpurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is bene...

Страница 8: ...ure for purpose of input adjustment NG Models 5 to 10 5 W C Gas supplier provide external regulator for natural gas INSTALLATION Continued WARNING Never connect heater to private non utility gas wells...

Страница 9: ...heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Pressure Testing Heater Gas Connections 1 Open equipment shutoff valve see Figure 8 2 Open gas supply tank valve 3...

Страница 10: ...setthecontrolknobonELECTRIC position Do not set the control knob between the locked position otherwise there will be no power to the heater 1 STOP Read the safety information page 3 2 Make sure equipm...

Страница 11: ...t any air If you smell gas STOP Please check the gas connection There are three selections AUTO MAN and OFF a auto select of main burner Press BURNER button the flame is on AUTO select Press or to set...

Страница 12: ...r about thirty 30 seconds This will allow air to bleed from the gas system 7 With control knob pressed in push down and release the ignitor button This will light pilot If needed keep pressing ignitor...

Страница 13: ...h Flame Figure 21 Injector Holder On Outlet Burner Tube WARNING Disconnect power be fore attempting any maintenance or cleaning to reduce the risk of fire elec tric shook or personal injury Turn off h...

Страница 14: ...passageways of h eater c lean Inspec t th ese areas of heater before each u se Have heat er in sp ec ted yearly by a qualified service person H e a t e r m a y n e e d m o r e f r e q u e n t c l e a...

Страница 15: ...ing Only a qualified service person should service and repair fireplace CAUTION Never use a wire needle or similar object to clean ODS pilot This can damage ODS pilot unit When pressing the button of...

Страница 16: ...s regulator Slight smoke or odor during initial operation 1 Residues from manufacturing processes 2 Not enough air 3 Gas regulator defective 1 Problem will stop after a few hours of operation 2 Check...

Страница 17: ...PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call KOZY WORLD s toll free number at 814 643 1775 for referral information When ca...

Страница 18: ...18 ILLUSTRATED PARTS BREAKDOWN GFN2815R GFP2816R GFN2817R GFP2818R GFN2819R GFP2820R...

Страница 19: ...GFN2815R GFP2816R GFN2817R GFP2818R GFN2819R GFP2820R This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 17 of...

Страница 20: ...20 ILLUSTRATED PARTS BREAKDOWN GFN2815R GFP2816R GFN2817R GFP2818R GFN2819R GFP2820R...

Страница 21: ...This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 17 of this manual GFN2815R GFP2816R refer to W column GFN28...

Страница 22: ...n the front angle See FIG 4 FIG 3 FIG 4 STEP 4 Insert the pinhole on the upper part on the left side of log 1 Place the lower part of log 4 on the flat roof at the left side of log 3 See FIG 5 STEP 5...

Страница 23: ...23 Mantel Installation Instructions...

Страница 24: ...onnectors on the left part of top base panel in the corresponding holes of left base panel see FIG b Then screw down the connectors using Philips screwdriver see FIG c 3 Piece together the right base...

Страница 25: ...ssembled structure and front base panel marked 4 Note Insert the connectors on the front base panel in the seven corresponding holes of assembled struc ture see FIG g Then screw down the connectors us...

Страница 26: ...lf tapping screws and anchors as shown in FIG 1 assembling the anchors see page 28 Tear the dust proofplasticfilmoff regulator Connectoneendofhosemetal fitting provide with fireplace to regulator and...

Страница 27: ...27 Install base Push base to mantel and ensure the rear part of the base fits with the col umn face closely see FIG 3 FIG 2 FIG 3...

Страница 28: ...lls wall areas between studs or solid walls concrete or masonry a Drill holes at marked locations using 5 16 drill bit For solid walls concrete or masonry drill at least 1 deep b Fold wall anchor as s...

Отзывы: