Kozy-World GFD4360 Скачать руководство пользователя страница 1

               

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 

  

  Do not store or use gasoline or other flammable vapors and liquids in vicinity of 

this or any other appliance. 

 

WHAT TO DO IF YOU SMELL GAS 

·

 

Do not try to light any appliance. 

·

 

Do not touch any electrical switch; do not use any phone in your building. 

·

 

Immediately call your gas supplier from a neighbor

s phone. Follow the gas 

supplier

s instructions. 

·

 

If you cannot reach your gas supplier, call the fire department. 

 

  Installation and service must be performed by a qualified installer, service agency 

or the gas supplier. 

VENT-FREE GAS FIREPLACE  

GFD4360 

INSTALLER: DO NOT DISCARD THIS MANUAL 

 LEAVE FOR HOMEOWNER

FUTURE REFERENCE.

 

 

WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED 
EXACTLY, A FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL 
INJURY, OR LOSS OF LIFE. 

WM-GFD4360-0903 

CAUTION 

 FOR YOUR SAFETY

 

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is 
installed. Provisions for adequate combustion and ventilation air must be provided. 
Refer to 

Air for Combustion and Ventilation

 section on page 7 of this manual.

 

 

This appliance may be installed in an aftermarket, permanently located manufactured 
(mobile) home, where not prohibited by local codes. This appliance is for use with the 
type of gas indicated on the rating plate only. This appliance is not convertible for use 
with other gases. 

 

WARNING:  

This appliance is equipped 

for  (Natural  and  Propane)  gas.  Field 
conversion  is  not  permitted  other  than 
between natural or propane gases. 

 

Kozy-World

 

®

 

Questions

problems,  missing parts? 

 Before returning to your retailer, call the KOZY WORLD PHONE 

NUMBER (814)643-1775 
   

Содержание GFD4360

Страница 1: ...RE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE WM GFD4360 0903 CAUTION FOR YOUR SAFETY This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on page 7 of this manual This appliance may be installed in an aftermar...

Страница 2: ...lly before starting installation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS MODEL NO GFD4360 Input Rating 32 000 BTU Hr 32 000 BTU Hr Gas Type Natural LP Propane Ignition Electronic Piezo Electronic Piezo Manifold Pressure 4 in W C 9 in W C Inlet Gas Pressure Maximum 10 5 in 14 in Minimum 5 in 11 in Dimensions inches ...

Страница 3: ... alter burner flame patterns WARNING Do not use a blower insert heat exchange insert or other accessory not approved for use with this heater Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flammable material on or near the appliance Never place any objects in the heater Heater becomes very hot when runnin...

Страница 4: ...e 20 15 Do not add extra logs or ornaments such as pine cones vermiculite or rock wool Using these added items can cause sooting Do not add lava rock around base Rock and debris could fall into the control area of heater After servicing always replace screen before operating heater 16 This heater is designed to be smokeless If logs ever appear to smoke turn off heater and call a qualified service ...

Страница 5: ...de by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented propane or natural gas fired space heaters shall be prohibited in bedrooms and bathrooms In the State of Massachusetts the gas cock mus...

Страница 6: ... one 1 ounce 30ml of water for every 1 000 BTUs 3kWs of gas input per hour An unvented room heater is recommended as a supplemental heater a room rather than a primary heat source an entire house In most supplemental heat applications the water vapor does not create a problem In most applications the water vapor enhances the low humidity atmosphere experienced during cold weather The following ste...

Страница 7: ...n which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are connecting only if there are door less passageways or ventilation grills between them Unusual...

Страница 8: ...stion air from the outdoors and vents to the outdoors 4 Compare the maximum BTU hr the space can support with the actual amount of BTU hr used BTU hr maximum the space can support BTU hr actual amount of BTU hr used Example 51 200 BTU hr maximum the space can support 56 000 BTU hr actual amount of BTU hr used The space in the above example is a confined space because the actual BTU hr used is more...

Страница 9: ...ide two permanent openings one within 12 inches of the ceiling and one within 12 inches of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANSI Z223 1 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for in...

Страница 10: ...lamps etc in the air exist may discolor walls WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventilatio...

Страница 11: ...ied equipment shutoff valve with 1 8 in NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING Never connect heater to private non utility gas wells This gas is commonly known as wellhead gas The installer must supply an external regulator The external regulator will reduce incoming gas pressure You ...

Страница 12: ...ge to regulator Hold gas regulator with wrench when connecting into gas piping and or fittings NG Models 5 in to 10 5 in W C Gas supplier provide external regulator for natural gas Purchase the optional CSA design certified equipment shut off valve from your dealer See Accessories Minimum inlet pressure for purpose of input adjustment CAUTION Two gas line installations at the same time are forbidd...

Страница 13: ... the width of a quarter and turn knob counterclockwise until the knob locks into the LP position see Figure 10 Selection valve must be locked into either the LP position or the NG position 3 Rotate and close cover over gas selection valve and reinstall screw 4 Remove hex plug from LP gas inlet of regulator and install into NG inlet of regulator use thread sealant to assure there are no leaks Figur...

Страница 14: ...g system Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 11 2 Pressure supply piping system by either using compressed air or opening gas su...

Страница 15: ...these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury CAUTION After installation and periodically thereafter check to ensure that no flame comes in contact with any log With the heater set to high check to see if flames contact any log If so reposition logs according to the log installation instructions in this manual Fl...

Страница 16: ...is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push control Never use tools If...

Страница 17: ...n for 30 seconds after lighting pilot After 30 seconds release control knob Note If pilot goes out repeat steps 3 through 7 This heater has a safety interlock system Wait one 1 minute before lighting pilot again 8 Warning Make sure while the input gas type is NG pilot burner NG ignites while the input type is LP pilot burner LP ignites Note If you find anything abnormal in this step repeat steps 2...

Страница 18: ...ling forward 2 Follow steps 1 through 5 under Lighting Instructions 3 With Control Knob in PILOT position strike match and hold near pilot Press in Control Knob pilot should light 4 Keep Control Knob pressed in for 30 seconds after lighting pilot After 30 seconds release Control Knob 5 Make sure the heater screen is in place before operating heater Figure 14 ON OFF Switch location ...

Страница 19: ...e 21 23 BURNER FLAME PATTERN Figure 17 shows a correct burner flame pattern Figure 18 shows an incorrect burner flame pattern If pilot flame pattern is incorrect as shown in Figure 18 Turn heater off see To Turn off Gas to Appliance page 18 See Troubleshooting pages 21 through 23 BURNER PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting at the entrance to the burner Th...

Страница 20: ...air no greater than 30 PSI You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner pilot and primary air inlet holes on injector holder for dust an...

Страница 21: ...rong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace electrode 2 Replace electrode 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Replace ignitor cable 6 Replace piezo ignitor 7 Replace battery When igni...

Страница 22: ...er Service 3 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see cleaning and maintenance Page 20 or Contact Customer Service Burner backfiring during combustion 1 Burner orifice is clogged or damaged 2 Burner is damaged 3 Gas regulator is damaged 1 Clean burner orifice see cleaning and mai...

Страница 23: ...furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax and carpet cleaner or similar products Heater produces unwanted odors 1 Heater is burning vapors from paint hair spray glues etc See IMPORTANT statement page 21 2 Gas leak See Warning Statement at the top of page 21 3 Low fuel supply 1 Ve...

Страница 24: ...d serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call Customer Service toll free at 814 643 1775 for referral information When calling Customer...

Страница 25: ...ox 1 5 FHL001 01D Top Panel 1 6 FHL001 02D Body Wrap Panel 1 7 FHL001 03D Bottom Panel 1 8 FB 05AM Side Panel 1 9 FB 03AM Base 1 10 FB 02AM Upper Panel 1 11 FBB104 Screen 1 12 FBB500 Logs 1 13 FBD400T600 Burner Assembly 1 14 FBD400T850 ODS Outlet Tube 1 15 NDD0308 x 400 ODS 1 16 FBD400T840 ODS Outlet Tube 1 17 FBD400T830 ODS Inlet Tube 1 18 YDF06 Gas Selector Valve Assembly 1 19 FBD400T810 Outlet ...

Страница 26: ...26 Printed in China ...

Страница 27: ...RE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE WM GFD4360 0903 CAUTION FOR YOUR SAFETY This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on page 7 of this manual This appliance may be installed in an aftermar...

Страница 28: ...lly before starting installation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS MODEL NO GFD4360 Input Rating 32 000 BTU Hr 32 000 BTU Hr Gas Type Natural LP Propane Ignition Electronic Piezo Electronic Piezo Manifold Pressure 4 in W C 9 in W C Inlet Gas Pressure Maximum 10 5 in 14 in Minimum 5 in 11 in Dimensions inches ...

Страница 29: ... alter burner flame patterns WARNING Do not use a blower insert heat exchange insert or other accessory not approved for use with this heater Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flammable material on or near the appliance Never place any objects in the heater Heater becomes very hot when runnin...

Страница 30: ...e 20 15 Do not add extra logs or ornaments such as pine cones vermiculite or rock wool Using these added items can cause sooting Do not add lava rock around base Rock and debris could fall into the control area of heater After servicing always replace screen before operating heater 16 This heater is designed to be smokeless If logs ever appear to smoke turn off heater and call a qualified service ...

Страница 31: ...de by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented propane or natural gas fired space heaters shall be prohibited in bedrooms and bathrooms In the State of Massachusetts the gas cock mus...

Страница 32: ... one 1 ounce 30ml of water for every 1 000 BTUs 3kWs of gas input per hour An unvented room heater is recommended as a supplemental heater a room rather than a primary heat source an entire house In most supplemental heat applications the water vapor does not create a problem In most applications the water vapor enhances the low humidity atmosphere experienced during cold weather The following ste...

Страница 33: ...n which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are connecting only if there are door less passageways or ventilation grills between them Unusual...

Страница 34: ...stion air from the outdoors and vents to the outdoors 4 Compare the maximum BTU hr the space can support with the actual amount of BTU hr used BTU hr maximum the space can support BTU hr actual amount of BTU hr used Example 51 200 BTU hr maximum the space can support 56 000 BTU hr actual amount of BTU hr used The space in the above example is a confined space because the actual BTU hr used is more...

Страница 35: ...ide two permanent openings one within 12 inches of the ceiling and one within 12 inches of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANSI Z223 1 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for in...

Страница 36: ...lamps etc in the air exist may discolor walls WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventilatio...

Страница 37: ...ied equipment shutoff valve with 1 8 in NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING Never connect heater to private non utility gas wells This gas is commonly known as wellhead gas The installer must supply an external regulator The external regulator will reduce incoming gas pressure You ...

Страница 38: ...ge to regulator Hold gas regulator with wrench when connecting into gas piping and or fittings NG Models 5 in to 10 5 in W C Gas supplier provide external regulator for natural gas Purchase the optional CSA design certified equipment shut off valve from your dealer See Accessories Minimum inlet pressure for purpose of input adjustment CAUTION Two gas line installations at the same time are forbidd...

Страница 39: ... the width of a quarter and turn knob counterclockwise until the knob locks into the LP position see Figure 10 Selection valve must be locked into either the LP position or the NG position 3 Rotate and close cover over gas selection valve and reinstall screw 4 Remove hex plug from LP gas inlet of regulator and install into NG inlet of regulator use thread sealant to assure there are no leaks Figur...

Страница 40: ...g system Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 11 2 Pressure supply piping system by either using compressed air or opening gas su...

Страница 41: ...these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury CAUTION After installation and periodically thereafter check to ensure that no flame comes in contact with any log With the heater set to high check to see if flames contact any log If so reposition logs according to the log installation instructions in this manual Fl...

Страница 42: ...is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push control Never use tools If...

Страница 43: ...n for 30 seconds after lighting pilot After 30 seconds release control knob Note If pilot goes out repeat steps 3 through 7 This heater has a safety interlock system Wait one 1 minute before lighting pilot again 8 Warning Make sure while the input gas type is NG pilot burner NG ignites while the input type is LP pilot burner LP ignites Note If you find anything abnormal in this step repeat steps 2...

Страница 44: ...ling forward 2 Follow steps 1 through 5 under Lighting Instructions 3 With Control Knob in PILOT position strike match and hold near pilot Press in Control Knob pilot should light 4 Keep Control Knob pressed in for 30 seconds after lighting pilot After 30 seconds release Control Knob 5 Make sure the heater screen is in place before operating heater Figure 14 ON OFF Switch location ...

Страница 45: ...e 21 23 BURNER FLAME PATTERN Figure 17 shows a correct burner flame pattern Figure 18 shows an incorrect burner flame pattern If pilot flame pattern is incorrect as shown in Figure 18 Turn heater off see To Turn off Gas to Appliance page 18 See Troubleshooting pages 21 through 23 BURNER PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting at the entrance to the burner Th...

Страница 46: ...air no greater than 30 PSI You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner pilot and primary air inlet holes on injector holder for dust an...

Страница 47: ...rong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace electrode 2 Replace electrode 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Replace ignitor cable 6 Replace piezo ignitor 7 Replace battery When igni...

Страница 48: ...er Service 3 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see cleaning and maintenance Page 20 or Contact Customer Service Burner backfiring during combustion 1 Burner orifice is clogged or damaged 2 Burner is damaged 3 Gas regulator is damaged 1 Clean burner orifice see cleaning and mai...

Страница 49: ...furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax and carpet cleaner or similar products Heater produces unwanted odors 1 Heater is burning vapors from paint hair spray glues etc See IMPORTANT statement page 21 2 Gas leak See Warning Statement at the top of page 21 3 Low fuel supply 1 Ve...

Страница 50: ...d serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call Customer Service toll free at 814 643 1775 for referral information When calling Customer...

Страница 51: ...ox 1 5 FHL001 01D Top Panel 1 6 FHL001 02D Body Wrap Panel 1 7 FHL001 03D Bottom Panel 1 8 FB 05AM Side Panel 1 9 FB 03AM Base 1 10 FB 02AM Upper Panel 1 11 FBB104 Screen 1 12 FBB500 Logs 1 13 FBD400T600 Burner Assembly 1 14 FBD400T850 ODS Outlet Tube 1 15 NDD0308 x 400 ODS 1 16 FBD400T840 ODS Outlet Tube 1 17 FBD400T830 ODS Inlet Tube 1 18 YDF06 Gas Selector Valve Assembly 1 19 FBD400T810 Outlet ...

Страница 52: ...26 Printed in China ...

Отзывы: