Kozy-World FMK4023 Скачать руководство пользователя страница 1

                                                                                                                

   FULL SIZE VENT-FREE
            FIREPLACE

OWNER

S OPERATION AND INSTALLATION MANUAL

    

W ARNING:  If  the  information  in this

manual  is  not  followed  exactly,a  f ire  or
ex plosi on  m ay  resul t causing  property
damage,personalinjury,  or  loss  of  life.

    

WARNING

:  

 

T

his  is  an  unvented gas-fired

fireplace.It  uses  air  (oxygen)  f r om   t he  r oom
i n   whi c h    i t    i s installed.  Prov isions  for
adequate combustion

 

 and  ventilation  air  must

be  pr ov ided.  Ref er  t o  A ir   For Combus-
tion  and  Ventilation section on  page  4  of  this
manual.

Do  not  store  or  use  gasoline  or  other  flammable
vapors  and  liquids  in  the  vicinity  of  this  or  any
other  appliance.

WHAT  TO  DO  IF  YOU  SMELL  GAS

Do  not  try  to  light  any  appliance.

Do   not  touch   any   electrical   switch;  do

      not use  any  phone  in   your  building.

Immediately   call   your  gas  supplier  from

      a neighbor

s  phone. Follow  the gas  supplier

s

      instructions.

If   you   cannot  reach  your  gas  supplier,

      call  the  fire  department. Installation  and  ser
     vice   must   be    performed  by   a   qualified
      installer,service agency,or local gas supplier.

    

WARNING:  Improper   installation,

adjustment, alteration, service  or  mainte-

nance can  cause  injury  or  property  damage.

Refer  to  this  manual  for  correct  installation

and operational  procedures.  For  assistance

or  additional  information, consult  a  qualified

installer,  service  agency,  or  local  gas  supplier.

This  appliance  may  be  installed  in  an after-

market*,  permanently  located, manufactured

(mobile) home, where  not  prohibited  by

local codes.

This appliance  is  only  for  use  with  the  type  of

gas    indicated    on    the    rating    plate.  This

appliance  is  not  convertible  for  use  with  other

gases.

*Aftermarket: Completion  of  sale, not  for  purpose  of  resale,
from  the  manufacturer.

Safety Information Warnings......................................2

Product Identification...................................................3

Air for Combustion and Ventilation...........................4

Installation.....................................................................6

Operating heater.........................................................10

Cleaning&Maintenance.............................................10

Trouble Shooting.........................................................11

Specifications..............................................................13

Replacement Parts.....................................................14

Parts List.......................................................................15

Installing the Heater....................................................19

  

 Table of Contents

Installer: Please leave these instructions with the
   consumer.

Consumer: Please retain these instructions for future
use.

WATER VAPOR: A BY-PRODUCT OF NOVENTED ROOM
HEATERS

Water vapor is a by-product of gas combustion.An unvented
room heater produces approxinately one(1) ounce (30ml)
of water for every 1,000 BTU

s(3KW

s) of gas input per

hour. Refer to page 3.

Kozy-World

R

World-Marketing of American,Inc.
P.O.Box 192,Rt.22 West
MillCreek,PA 17060

KOZY-WORLD PHONE NUMBER:(814)643-1775
      http://www.worldmkting.com

FMK4023

FMK4024

FMK4025

FMK4026

Содержание FMK4023

Страница 1: ... Refer to this manual for correct installation and operational procedures For assistance or additional information consult a qualified installer service agency or local gas supplier This appliance may be installed in an after market permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This...

Страница 2: ...e LP supply tank s indoors 3 If you smell gas l Shut off gas supply l Do not try to light any appliance lDo not touch any electrical switch do not use any phone in your building l Immediately call your gas sup plier from a neighbor s phone Follow the gas supplier s instructions lIf you cannot reach your gas supplier call the fire department 4 This fireplace shall not be installed in a bedroom or b...

Страница 3: ...arefully unwrap logs 10 Check for any shipping damage If fireplace or any logs are damaged promptly inform dealer where you bought the fireplace PRODUCT FEATURES SAFETY PILOT This fireplace has a pilot with an Oxygen Depletion Sensing ODS safety shutoff system The ODS pilot is a required feature for vent free fireplace The ODS pilot shuts off the fireplace if there is not enough fresh air PIEZO IG...

Страница 4: ... Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms 1 Determine the volume of the space length width height Length Width Height cu ft volume of space Example Space size 20ft...

Страница 5: ...he room unconfined Figure 2 Ventilation Air From Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr WARNING If the area in which the fireplace may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction provide adequate combustion and ventilation air by one of the methods described ...

Страница 6: ...xt to vinyl or cloth wall coverings or operating fireplace where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosenelamps etc in the air exist may discolor walls CHECK GAS TYPE Use only the type of gas indicated on the plate If your gas supply can not meet that requirement do not install fireplace Call dealer where you bought fireplace for proper type fireplace Figure...

Страница 7: ...eplace to private non utility gas wells This gas is commonly known as wellhead gas CAUTION Use only new black iron or steel pipe Internally tinned cop per tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to fireplace If pipe is too small undue loss of pressure will occur Installation must include an equipment shutoff valve un...

Страница 8: ...Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect fireplace and equip ment shutoff valve to gas supply Check reconnected fittings for leaks Pressure Testing fireplace Gas Connections 1 Open equipment shutoff valve see Figure 8 Figure 9 Checking Gas Joints INSTALLATION Continued CHECKINGGASCONNECTIONS 2 Open gas supply valve 3 M...

Страница 9: ...control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out an y g as Th en smell for gas including near the floor If you smell gas STOP Follow B in the safety information page 2 If you don t smell gas go to the next step 5 Turn control knob counterclockwise to the PILOT position Press in control knob for five seconds see Figure 11 Note You may be running this fireplace for the f...

Страница 10: ...see to Turn Off Gas to Appliance page 9 l see Troubleshooting pages 11 through 12 CLEANINGANDMAINTENANCE WARNING Turn off fireplace and let cool before cleaning CAUTION You must keep c o n t r o l a r ea s b u r n e r an d circulating air passageways of fireplace clean Inspect these areas of fireplace before each use Have fireplace inspected yearly by a qualified service person H e a t e r m a y n...

Страница 11: ...lame holes may become blocked by debris or rust with no flame present If so turn off fireplace and let cool Either remove blockage or replace burner Blocked burner flame holes will create soot TROUBLE SHOOTING Note All troubleshooting items are listed in order of operation WARNING Turn off and let cool before servicing Only a qualified service person should service and repair fireplace CAUTION Nev...

Страница 12: ...ted 1 C l e a n b u r n e r s e e C l e a n i n g and Maintenance page 10 or replace burner orifice 2 Contact local propane LP gas company 3 Replace burner orifice 4 Reconnect leads see wiring diagram Delayed ignition burner 1 Manifold pressure is too low 2 Burner orifice clogged 1 Contact local gas company 2 Clean burner see Cleaning and Maintenance page 10 Burner backfiring during combustion 1 D...

Страница 13: ...et Gas Pressure In of water Maximum 14 10 5 Minimum 11 5 Dimensions Inches H W D Heater 48 X42 5 16 X 14 1 2 48 X42 5 16 X 14 1 2 Carton 46 X 46 1 2 X 17 1 2 46 X 46 1 2 X 17 1 2 Weight Lb Stove 145 143 145 143 Shipping 165 162 165 162 For purposes of input adjustment The weight of FMK4023 FMK4024 FMK4024 FMK4026 FMK4023 FMK4025 ...

Страница 14: ...e factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product or Parts Central If they can t supply original replacement part s call KOZY WORLD at 814 643 1775 for referral information When calling KOZY WORLD have ready l Model number of your fireplace l The replacement part number REPLACEMENT ACCESSORIES Purchase these fireplace accessories f r o m yo u r lo c al d ealer o r P ar ...

Страница 15: ...PARTS LIST This list contains replaceable parts used in your fireplace When ordering parts follow the instructions listed under Re placement Parts on page 14 of this manual FMK4023 FMK4025 FMK4024 FMK4026 ...

Страница 16: ...16 Parts list FMK4023 FMK4025 FMK4024 FMK4026 ...

Страница 17: ...17 ILLUSTRATED PARTS BREAKDOWN FMK4025 FMK4026 ...

Страница 18: ...18 ILLUSTRATED PARTS BREAKDOWN FMK4023 FMK4024 ...

Страница 19: ...ireplace l Fasten decorating logs 1 2 3 onto the correspondent angle iron Figure 6 l Fasten decrations logs 4 onto the correspondent angle iron in front of fixbox see figure 7 l Insert the pinhole in the upper part of log 4 into the pin on the left side of log 1 Place the lower part on the flat roof at the left side of log 3 Figure 8 l Insert the pinhole in the upper side of log 5 into the pin on ...

Страница 20: ...n control housing just inside control compartment door in front of stove Using two black screws provided in blower kit mount blower operation control housing to mounting tab in left side of lower control compartment see Figure 14 F 7 Check to make sure that the power cord is completely clear of blower wheel and there are no foreign objects in blower wheel 8 Use screws provided in blower kit to ass...

Страница 21: ...21 20 6028 ...

Страница 22: ......

Отзывы: