kozy heat NCK-SL42-SPB Скачать руководство пользователя страница 1

EN

FR
PG
5

HUSSONG MANUFACTURING CO., INC.

NATURAL GAS CONVERSION KIT 
#NCK-SL42-SPB

For use with the Slayton-42S #SLA-42S 

Direct Vent Gas Fireplace

This fireplace is certified under U.S. and Canadian standards ANSI Z21.88-2017/CSA 2.33-2017 and CSA 2.17 2017

WARNING

This conversion kit shall be installed by a 

qualified service agency in accordance 

with the manufacturer’s instructions and 

all applicable codes and requirements 

of the authority having jurisdiction. If 

the information in these instructions is 

not followed exactly, a fire, explosion 

or productions of carbon monoxide 

may result, causing property damage, 

personal injury, or loss of life. The 

qualified service agency is responsible 

for proper installation of this kit. The 

installation is not proper and complete 

until operation of the converted 

appliance is checked as specified in the 

manufacturer’s instructions supplied 

with the kit. Refer to appliance owner’s 

manual or product data plate for proper 

inlet and manifold pressure adjustments 

and orifice sizing.

IMPORTANT

THE CONVERSION SHALL BE CARRIED OUT BY A 
MANUFACTURER’S AUTHORIZED REPRESENTATIVE, 
IN ACCORDANCE WITH THE REQUIREMENTS 
OF THE MANUFACTURER, PROVINCIAL OR 
TERRITORIAL AUTHORITIES HAVING JURISDICTION 
AND IN ACCORDANCE WITH THE REQUIREMENTS 
OF THE CAN/CGA-B149.1 OR CAN/CGA-B149.2 
INSTALLATION CODES.

CETTE CONVERSION DE GAZ DOIT ÊTRE EFFECTUÉE 
PAR UN REPRÉSENTANT AUTORISÉ DU FABRICANT, 
CONFORMÉMENT AUX EXIGENCES DU FABRICANT ET 
DES AUTORITÉS PROVINCIALES OU TERRITORIALES 
AYANT JURIDICTION, ET AUX EXIGENCES DES 
CODES D’INSTALLATION CAN/CGA-B149.1 OU CAN/
CGA-B149.2.

READ ALL STEPS BEFORE STARTING INSTALLATION.  

LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE.

This gas conversion kit installation instructions must be used in 
conjunction with the installation and operation manual provided with 
the appliance. Please read the appliance owner’s manual completely 
before performing any procedures in these instructions. All warnings, 
precautions, and instructions outlined in the manual provided with 

the appliance will continue to apply to these instructions. 

AVERTISSEMENT

Ce kit de conversion doit être installé 

par une agence d’entretien qualifiée, 

selon les instructions du fabricant et 

tous codes et règlements applicables 

de l’autorité ayant juridiction. Le non-

respect de ces instructions peut créer un 

incendie, une explosion ou la production 

de monoxyde de carbone, et causer des 

dommages matériels, des blessures 

ou même la mort. L’agence d’entretien 

qualifiée est responsable de la qualité 

d’installation de ce kit. L’installation ne 

sera conforme et complète qu’après 

avoir vérifié le fonctionnement du foyer 

converti, tel que spécifié dans les 

instructions du propriétaire fournies 

avec ce kit. Voir le manuel d’utilisation 

ou la plaque signalétique de l’appareil, 

pour les réglages de pressions d’entrée 

et du manifold et les dimensions d’orifice 

(injecteur) de brûleur/veilleuse.

Hussong Manufacturing Co., Inc. 
P.O. Box 577, 204 Industrial Park Drive 
Lakefield, MN 56150-0577, USA

SLA-42S • Rev. 4, 8/19

Report Number: 19-505

Содержание NCK-SL42-SPB

Страница 1: ...RMÉMENT AUX EXIGENCES DU FABRICANT ET DES AUTORITÉS PROVINCIALES OU TERRITORIALES AYANT JURIDICTION ET AUX EXIGENCES DES CODES D INSTALLATION CAN CGA B149 1 OU CAN CGA B149 2 READ ALL STEPS BEFORE STARTING INSTALLATION LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE This gas conversion kit installation instructions must be used in conjunction with the installation and operation manual provided with th...

Страница 2: ......

Страница 3: ...rner tube from its mounting cradles Step 3 Remove existing orifice caps Step 4 Replace with the orifice caps included with this kit Tighten caps securely The sizes are stamped on the orifices Table 1 Burner Orifice Sizes at Elevations 0 4 500 ft 1 372 m Fuel Center Burner Side Burners NG 37 DMS 54 DMS Figure 1 Burner Orifice BURNER ORIFICE C Convert Pilot Assembly Step 1 Using a 7 16 wrench loosen...

Страница 4: ...ng is between the recommended low and high pressure settings See Table 4 Step 4 Turn off pilot and burner Step 5 Disconnect hose and tighten the outlet pressure tap screw clockwise The screw should be snug do not over tighten Step 6 Relight the pilot and burner Step 7 Reattach the manometer to the outlet pressure tap to verify tap is completely sealed Manometer should read no pressure Table 4 Mani...

Страница 5: ... brûleur latéraux des supports de fixation Étape 2 Retirer le tube de brûleur central de ses supports de fixation Étape 3 Remplacez le par le nouvel orifice de brûleur fourni avec le kit numéro marqué sur l orifice du brûleur en veillant à bien serrer l orifice du brûleur Tableau 1 Dimension d orifice du brûleur Élévation 0 4500 pi 1372m Combustible Central Latéraux NG 37 DMS 54 DMS ORIFICE DU BRÛ...

Страница 6: ... doit être vissée juste assez ne la vissez pas trop serrée Étape 6 Rallumez la veilleuse et le brûleur Étape 7 Branchez le manomètre au raccord de test de pression du manifold pour vérifier qu il est étanche Le manomètre ne devrait indiquer aucune pression lorsque la veilleuse et le brûleur sont allumés Tableau 4 Pression de gaz au manifold Combustible Minimum Low Maximum High NG 1 1 po WC 0 27 kP...