Kozy Power Vent #KPV
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
7
2.3 Draft Bypass Adjustment
NOTE: All Kozy Power Vent systems will be shipped with the draft
bypass in setting 5. Adjustment of the draft bypass setting would only
occur during troubleshooting or flame appearance adjustments.
The draft bypass system is factory set to setting 5; for certain vent
runs the draft bypass system will need to be adjusted. To adjust the
draft bypass, loosen the locking screw. Adjust clock wise or counter
clockwise depending on your specific installation. See Figures 2.4,
2.5, and 2.6.
Table 2.2, Callaway 72 - Draft Bypass Setting Chart
Natural Gas
Propane
Draft Setting
#1
Not Allowed
Allowed*
#2
Not Allowed
Allowed*
#3
Allowed
Allowed
#4
Allowed
Allowed
#5
Allowed
Allowed
* This draft setting is allowed on all vent configurations except a vent
configuration with a vertical drop
Figure 2.6, Loosen Locking Screw
Figure 2.7, Adjust the Draft Bypass
Figure 2.8, Shown in Position 3