Clearances to Combustibles
SECTION 3
FRAMING
#CAR-39
R.11 February 2022
15
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES
3.5 Clearances to Combustibles
Table 3.1, Minimum Appliance Clearances to Combustible Material
From appliance top stand-off assembly
0”
0mm
From appliance left and right stand-off brackets
0”
0mm
From appliance back stand-off brackets
0”
0mm
From appliance corners
1/4”
6mm
From appliance front
36”
914mm
Appliance side to adjacent sidewall
1-1/4”
32mm
Appliance top to 3/4” (19mm) trim
10”
254mm
Mantel 10” (254mm) deep from appliance top
14”
356mm
Appliance top to fireplace enclosure top
30”
762mm
Minimum height of fireplace enclosure
64-1/2”
1638mm
1”
(25mm)
22”
(559mm)
39
¾
”
(1010mm)
12
9⁄16
”
(318mm)
¼
”
(6mm)
44
5⁄16
”
(1125mm)
31
5⁄16
”
(796mm)
62
5⁄8
”
(1591mm)
1”
(25mm)
22”
(559mm)
39
¾
”
(1010mm)
39
¾
”
(1010mm)
Typical Corner Installation
Typical Horizontal Installation
Typical Vertical Installation
Includes 1/2” (13mm) typical finish
with flush mount
FIGURE 3.4
Clearance to Combustibles
Nominal 2“ x 4” framing used in enclosure framing