Kospel EKCO.L3 Скачать руководство пользователя страница 1

Electric Central Heating Flow Boiler

EKCO.L3

EKCO.LN3

Assembly and operating instructions

Содержание EKCO.L3

Страница 1: ...Electric Central Heating Flow Boiler EKCO L3 EKCO LN3 Assembly and operating instructions...

Страница 2: ...shall not be made by children without supervision Used product can t be treated as general communal waste Disassembled appliance has to be delivered to the collection point of electrical and electron...

Страница 3: ...al and hydraulic work must be performed by a qualified professional installer in accordance with the manufacturer s instructions 9 All installation work must be performed when the power and water supp...

Страница 4: ...as applicable in accordance with binding norm Temperature of heating medium feed and return Capacity of central heating system Pressure in central heating system C l bar 85 70 56 1 5 70 55 80 55 45 12...

Страница 5: ...ion matches the arrow cast on the hull and the cover was at the bottom of the filter Filters can be mounted on horizontal and vertical pipelines It is recommended that using shut off valves immediatel...

Страница 6: ...iquid what influences on the durability of immersion heaters 4 Vent the central heating system 5 Connect a boiler to the electrical system 6 Assemblyandconnecttheroomregulator sensor and other devices...

Страница 7: ...nductor connection 1 temperature limiter 2 additional conductors for one phase system only 1 1 N L PNL Connection to the three phase electrical system for boilers of 4 6 8kW you should delete conducto...

Страница 8: ...he type of power supply installation Type of electrical installation switch no 3 three phase one phase Note switches 1 2 must not be adjusted save the factory settings Output terminal block MA master...

Страница 9: ...091B_f 1157 9 AZV 642 L N PE L N PE LB LA N L N PE O G I M SUPPLY PUMP C TWV PUMP PUMP black brown blue Do not connect any voltage into MA RT Tcyl entries This can result in permanent controller dama...

Страница 10: ...MA entry voltage free entry so that when a master appliance gets on the contact opens and the boiler switches off it results in heating blockage and pump s standstill RT room temperature regulator Opt...

Страница 11: ...ces service configuration allows to heating system configuration to object s conditions available for installation company and specialized services after entering the access code and preview of input...

Страница 12: ...ging installation 4 preset temperature in the installation or symbol when heating is blocked by a signal from the main device 5 DHW cylinder temperature 6 executing of heating program 7 signalling of...

Страница 13: ...RATION DHW TEMPERATURE REGULATION INSIDE 1 no of time frame according to schedule max 5 2 start time of circulation pump operation 3 finish time of circulation pump operation CIRCULATION PROGRAM No 1...

Страница 14: ...nfection independent of the day s or time s set TIME DATE setting of the current system time YEAR MONTH DAY HOUR MINUTE AUTOMATIC TIME CHANGE Yes automatic system time changeover from summer to winter...

Страница 15: ...itation costs MAN the temperature of charging set point of temperature flow CH BOILER PROTECTION Yes if the temp of inside s sensor of boiler drops below 5 the circulation pipe will be turned on No pr...

Страница 16: ...procedure 10 min the pump works alternately with a maximal and minimal rotation speed Thanks to this air bubbles are concentrated and easier to remove from the installation H MAX pump s raising height...

Страница 17: ...cted time frame start editing chosen time frame and by pressing the dial go to command position select command delete and press the dial To add new time frame select last defined time frame and by pre...

Страница 18: ...stem MPa 0 05 0 5 bar Outlet temperature C 20 85 Max temperature C 100 Dimensions height x width x depth EKCO LN3 mm 716 x 316 x 235 EKCO L3 716 x 316 x 191 Weight EKCO LN3 kg 20 5 EKCO L3 15 8 Boiler...

Страница 19: ...3x2 5 3x4 3x6 5x2 5 Max power supply cable cross section mm 2 5 x 16 Max allowed network impedance 0 27 0 17 0 15 0 27 Boiler 12 16 20 24 Rated power kW 12 16 20 24 Rated voltage 400V 3N Rated curren...

Страница 20: ...KOSPEL S A 75 136 Koszalin ul Olchowa 1 tel 48 94 31 70 565 serwis kospel pl www kospel pl...