IP67 / IP68 Industrial Ethernet Switch
72
www.korenix.com
3.10.1.
Fault Relay Setting
This device provides 1 digital output, also known as Relay Output. The relay
contacts are energized (open) for normal operation and will close under faulty
conditions. Faulty conditions include Power Failure, Ethernet port Link Failure,
Ping Failure and Super Ring Topology Change. You can enable and select relay
trigger by clicking the Apply button.
Relay 1
Check the box Relay 1 and then select the Event Type and its
parameters.
Event Type
You will be given the following options: Dry Output, Power
Failure, Link Failure, Ping Failure and Super Ring Failure.
Each event type has its own parameters. A Relay can be
related one event type, detailed below
Dry Output
On Period (Sec)
Type in the amount of time you would like Relay Output to be
on. This can range from 0-4294967295 seconds.
Off Period (Sec)
Type in the amount of time you would like Relay Output to be
off. This can range from 0-4294967295 seconds.
When the amount of time is reached, the system will turn the Relay Output on or
off.