28
Electrical installation
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
4.11 Expansion modules with "internal" quick shutdown in two rows
PE
L ≤ 1,5 m
Netz/Line
X2
X1
X2
X1
Linie 1
Linie 2
Schnellabschaltung/
Fast Shutdown
10
10
5
8
6a
7
7
6b
7
7
12
12
9
9
L
LL ≤≤≤≤ 1,5 m
111 5
Netz/Line
et
et
et
et
ettz/
tz/
z/
z/
z/Li
/Li
/L
/LLL
3
4
2
1
Key:
1.
Mains filter )*
2.
Mains choke )*
3.
MotionOne CM )*
4.
Supply unit SO CM-P BG3 )*
5.
Axis controller SO CM BG3
6.
a Expansion module SO CM-E row 1 ("Dual" model)
b Expansion module SO CM-E row 2 ("Dual End" model)
7.
Axis controller SO CM BG1
8.
PE earthing rail
9.
PE connection SO CM-E = 16 mm
2
as per EN 61800-5-1
10.
Series protective earth conductor connection 16 mm
2
, optionally PE strap (article no.: 1400.807.0)
can be used.
11.
Connection of the supply connections
(only SO CM-E.x0xx.1(2)
:
• 24 V DC from expansion module row 1 to expansion module row 2 (X2) with standard two-core
cable.
• Connection from expansion module row 1 to expansion module row 2 (X1) only using pre-
assembled DC link cable, see Chapter A.5.2
12.
Connection of "internal" quick shutdown via X7/ ES
)* See Operation Manual Supply Unit SO CM-P BG3+4
CAUTION!
Risk of injury due to incorrect wiring!
Carelessness may result in injuries.
The "internal" quick shutdown is a safety feature. Make sure that all connections
have good contact and are sufficiently secure (2.1 Nm) that they cannot come
loose.
Figure 4.11 Connection example, expansion modules with "internal" quick shutdown in two rows
Содержание LTI MOTION ServoOne CM
Страница 1: ...Expansion module Compact multi axis system ServoOne CM ServoOne CM Operation Manual...
Страница 12: ...12 Safety Operation Manual Expansion Module SO CM E 1800 202B 0 01 Date 02 2019 2 8 Declaration of conformity...
Страница 30: ...30 Operation Manual Expansion Module SO CM E 1800 202B 0 01 Date 02 2019...
Страница 37: ...37 Operation Manual Expansion Module SO CM E 1800 202B 0 01 Date 02 2019...