background image

Keep This  Manual

With Heat Exchanger

KNHE20 SERIES  

WATER-TO-AIR

HEAT EXCHANGER

OPERATOR'S MANUAL

CAUTION

BEFORE INSTALLING AND

USING THIS HEAT EXCHANGER,

IT IS IMPORTANT THAT THIS

MANUAL BE READ AND

UNDERSTOOD THOROUGHLY

KOOLTRONIC, INC.

30 Pennington-Hopewell Road

Pennington, NJ 08534

609 • 466-3400

FAX: 609 • 466-1114

www.kooltronic.com

900-046-29 (12/18)
(CDR: 20111)

Find additional information on
this model at kooltronic.com or
use the Technical Documents
QR code below.

Technical

Documents

Содержание KNHE20 Series

Страница 1: ...T EXCHANGER IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com 900 046 29 12 18 CDR 20111 Find additional information on this model at kooltronic com or use the Technical Documents QR code below Technical Documents ...

Страница 2: ...Kooltronic Heat Exchangers are designed to provide a cool environment for your electronic or electrical components There are models to fit virtually all sizes and shapes of electrical or electronic enclosures Our closed loop design also ensures that your components will not be exposed to hot dirty operating conditions This Manual provides you with the necessary general information for properly ins...

Страница 3: ...u read and thoroughly understand this Manual Before operating this unit all electrical wiring must be checked to assure the proper connections IV Product Identification and Nameplate Each Kooltronic Heat Exchanger includes an identification nameplate This nameplate provides CAUTION Operate this unit only on the proper voltages and frequencies as noted on the nameplate MODEL NO SERIAL NO MAX CABINE...

Страница 4: ... Water to Air systems are easy to install and usually require minimum maintenance The water used must be reasonably clean and cold enough to ensure proper operation of the cooling system under the most severe anticipated conditions In some cases if sufficiently cold water is available below ambient temperature cooling can be achieved Heated Air Blower Water with Heat Load Cold Water Heat Exchanger...

Страница 5: ...nclosure is about 05 inch 5 Install sealing washers on each screw from inside the enclosure and tighten see mounting drawing The Kooltronic Water To Air Heat Exchangers have been engineered to be installed easily These units utilize double layer gaskets The first gasket layer is placed on the outside perimeter of the front panel that is sealed against the customer enclosure The second layer is pla...

Страница 6: ...ger Options Internal corrosion resistant coatings Other voltages and frequencies Special materials or finishes Special motors line cords or connectors Model Volts Power Amps Watts Maximum Inlet Water Temp ºF ºC Performance Watts ºF ºC 0 25GPM 0 50GPM BTU H Watts 95ºF 35ºC Enclosure Air Temp 50ºF 10ºC Inlet Water Temp 0 25GPM 0 50GPM Approx Weight lbs kg KNHE20 115 0 30 33 85 29 20 5 36 9 21 5 38 7...

Страница 7: ...ing of Major Component Replacements earlier in this Manual VIII Packing Procedure Keep Heat Exchanger in proper upright position Pack Heat Exchanger in an appropriate carton preferably original carton if possible with adequate internal protective packaging making sure carton is marked properly For local controlled transportation strap carton where possible to a secure part of truck to prevent fall...

Страница 8: ...s received by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a suitable container for shipment preferably the original packaging if available All Heat Exchangers must be returned in an upright position properly secured to a pallet Improper packaging may void wa...