Portable Air Conditioner 18000 BTU
Operating Instructions
Model No. Kompact 18
Please read owner’s manual carefully before operating unit.
Страница 1: ...Portable Air Conditioner 18000 BTU Operating Instructions Model No Kompact 18 Please read owner s manual carefully before operating unit ...
Страница 2: ...NTROL PANEL AND MULTI COLOR DISPLAY 7 CONTROL PANEL FUNCTIONS 8 OPERATION USING THE CONTROL PANEL 9 COOLING 9 DEHUMIDIFYING 9 FANNING 9 AUTO MODE 9 SLEEP MODE 10 REMOTE CONTROL OPERATION 11 MAINTENANCE 13 END OF SEASON STORAGE 13 TROUBLESHOOTING 14 ERROR MESSAGES 14 DISCLAIMER 15 ...
Страница 3: ...supervision is necessary when the unit is used near children The unit in not intended for use by children 10 Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills 11 Do not expose skin or eyes directly to cool air for a long period of time 12 If an abnormal odor or smoke comes out of the unit disconnect the unit immediately and contact a qualified service technician...
Страница 4: ... A B C D F ACCESSORIES Flexible exhaust hose with 2 adapters 3 piece set stretches from 14 1 4 to 60 5 8 36cm to 150cm Window exhaust adapter Adjustable window slider kit 3 piece set adjusts 33 1 2 to62 85cm to 157 5cm Drain tube Drain pan BACK A Hot air outlet grill B Lower air inlet grill C Water Release Port c ...
Страница 5: ...HAUST HOSE Slide the square end of the exhaust duct over the hot air outlet on the back of the unit The exhaust hose should be kept as short and straight as possible Prevent any sharp bends in the exhaust hose as this will trap hot exhaust air The hot exhaust air can be vented through the wall or out a window If mounting in the wall the height of the hole should be 16 to 50 inches 40cm to 130cm ...
Страница 6: ...he length of the window kit to fit the opening If the window kit is not long enough connect the extra window kit panel to fit the opening Mark and cut down a single panel of the window kit if necessary 2 Place the window kit between the window and the window frame as shown in the images to the right Close the window onto the window kit to form a tight seal 3 Attach the exhaust duct adapter to the ...
Страница 7: ...uring the modes of cooling heating and fanning press this button to choose high medium or low fan speed In dehumidifying mode this button is inoperable when the unit is not working Press this button to turn the timer on This button decreases the room temperature timer hours Press this button to select among the modes of auto cooling dehumidifying fanning or heating Press this button to turn the un...
Страница 8: ... simultaneously to change the display from Celsius to Fahrenheit or vice versa TIMER KNOB when the unit is not working turn down konb to set the auto start time until the multi color display shows a flashing when the unit is working turn down konb to set the auto stop time press the Timer Off button and the multi color display will show a flashing turn letf and turn righ buttons to change the cloc...
Страница 9: ... display NOTE The unit operates at low fan speed during dehumidifying The unit cools the room slightly during dehumidification Keep the windows and the doors closed to aid in the effectiveness of the unit in removing the moisture from the room NOTE The unit will not dehumidify when the room temperature is lower than 61 F FANNING 1 Plug the power cord into a grounded outlet 2 Turn on the unit by pr...
Страница 10: ... MODE This mode can only be programmed from the remote control 1 The air conditioner will need to be in operation 2 Press the Sleep button The icon appears on the multi color display 3 The fan motor runs at low speed 4 When in cooling mode the temperature will increase 1 F per hour during the first two hours Then the temperature will stay 2 F higher than the originally set temperature for 6 hours ...
Страница 11: ...AA batteries provided Install the batteries before using the remote control The remote control can be used to do all the operations that can be programmed from the control panel The LCD display on the remote control can show either Celsius or Fahrenheit Press the and keys simultaneously to change the display from Celsius to Fahrenheit or vice versa ...
Страница 12: ...t NOTE If the water release port and water release pump are NOT used during periods of high humidity water will collect in a water container at the bottom of the unit When the water container is full the compressor will stop but the fan will continue to run When the water container is full the unit will display on the control panel until the tank is emptied To resume operation empty the water cont...
Страница 13: ...R Slide the filters out from the side of the unit Immerse the filter gently in warm water with a mild detergent Rinse thoroughly and dry before replacing An unclean air filter reduces air volume The filter should be cleaned every two weeks END OF SEASON STORAGE Turn off and unplug the unit Drain all condensate water from the water container Turn the unit to fan mode for a couple of hours to comple...
Страница 14: ...et Is the main power supply on Reestablish the main power supply Is the water container full indicator light on Empty the water container Unit does not operate or only runs in fan mode Is the timer set Change timer settings Is the air inlet or outlet blocked Clear the blocking Is there any other heat source in the room Move the heat source Are the air filters dirty Clean the air filters Is the tem...
Страница 15: ...HZ Cooling 9 6A Rated Current Heating 9 0A Sound Pressure Level 55db A Weight 43Kg net Dimensions 616x370 x780mm WxDxH Refrigerant R410A DISCLAIMER ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER COTTAGE STORES LLP HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN Koolbreeze is...