CPS3105
3.3 Board Installation
The CPS3105 is designed for use in a peripheral slot with support for one PCI Express interface (recom-
mended configuration for maximum bandwith: x4 PCI Express 3.0).
3.3.1 Hot Swap Insertion
Prior to following the steps below, ensure that the safety requirements are met.
To insert the CPS3105 in a running system proceed as follows:
1.
Ensure that the board ejection handle is open.
2.
Insert the board into the slot designated until it makes contact with the backplane connec-
tors.
3.
Using the ejector handle, engage the board with the backplane. When the ejector handle is
closed, the board is engaged.
The green PWR LED turns on indicating that the CPS3105 is operating.
4.
Fasten the front panel retaining screws.
3.3.2 Hot Swap Removal
Prior to following the steps below, ensure that the safety requirements are met. When removing a
board from the system, particular attention must be paid to the components which may be hot, such as
heat sink, etc.
To preclude damage or data loss when removing the CPS3105, ensure that the operating system has
been informed of the pending removal and that the OS has indicated that it is safe to proceed.
To remove the CPS3105 from a running system proceed as follows:
1.
Unlock the board ejection handle by pressing its release button.
The PWR LED turns off indicating that power has been removed from the CPS3105 and the
board may be removed from the system.
2.
Unscrew the front panel retaining screws.
3.
Using the ejector handle, disengage the board from the backplane and remove it from the
system.
3.3.3 XMC Module Installation
The CPS3105 supports the installation of an XMC module via the connector J2. For the initial installa-
tion and standard removal of the XMC module, refer to the documentation provided with the module.
Prior to installation or removal, ensure that the safety requirements are met. Particular attention must
be paid to the components which may be hot, such as heat sink, etc.