Installing the Board
3-5
The serial port 3 & 4 interrupt can be controlled in the following way.
CIS
Bit 1
Bit 0
IRQ 3
0 0
IRQ 4
0 1
IRQ 5
1 0
IRQ 7
1 1
The serial port 3 & 4 base address can be controlled in the following way.
CBAS
Bit 1
Bit 0
3F8
0 0
2F8
0 1
3E8
1 0
2E8
1 1
3.1.8 Uart 4 PnP Configuration
CPLD
Address
D7
D6
D5
D4
D3
D2
D1
D0
READ
n95*
CND4
CIS4_1 CIS4_0 CBAS4_
1
CBAS4_0
WRITE
n95*
CND4
CIS4_1 CIS4_0 CBAS4_
1
CBAS4_0
NU
Power-up Default
0
0
0
1
1
CND4
: When low, decode the base address
CIS4_
: [1..0] COM port interrupt select.
CBAS4_
: [1..0] COM base address select.
3.1.9 Digital
Watchdog
CPLD
Address
D7
D6
D5
D4
D3
D2
D1
D0
READ
n96*
WDEN
WDD2
WDD1
WDD0
NU
NU
NU
NU
WRITE
n96*
WDEN
WDD2
WDD1
WDD0
NU
NU
NU
NU
Power-up Default
0
0
0
1
WDEN
: Enable/disable digital watchdog.
WDD[2..0]
: Duration of digital watchdog.