Installing the Board
3-3
3.1.3 Register’s Description RS232/RS485
CPLD
Address
D7
D6
D5
D4
D3
D2
D1
D0
READ
n90h*
NU NU NU
RS485
RS232
ST1
NU NU
WRITE
n90h*
NU NU NU
RS485
RS232
ST1
NU NU
Power-up Default
0
1
0
ST1
: Enable RTS2 to be used as 485TX ENABLE when in 485 mode
RS232
: Enable UART2 RS232 operation
RS485
: Enable UART2 RS422 and 485 operation
The serial port 2 mode can be controlled by setting three bits. Here are the possibilities.
Mode
Bit RS485
Bit RS232
Bit ST1
RS232
0 1 X
RS422
1 0 0
RS485
1 0 1
X : Don’t care
3.1.4 History and Monitor Status
CPLD
Address D7
D6
D5
D4
D3
D2
D1
D0
READ
n91h*
PBRST
NU
WDO
NU NU NU NU PFO
WRITE
n91h*
NU NU NU NU NU NU NU NU
Power-up Default
PFO
: Read the external power fail flag
PBRST : When high, indicate that the last system reset was caused by push button reset
switch
WDO
: When high, indicate that the last system reset was caused by watchdog time out
Содержание cPCI-MXS64