Power Considerations
ID 1042-9252, Rev. 2.0
Page 5 - 3
P R E L I M I N A R Y
5.
Power Considerations
5.1
System Power
The considerations presented in the ensuing chapters must be taken into account by system
integrators when specifying the CP3002 system environment.
5.1.1
CP3002 Baseboard
The CP3002 baseboard itself has been designed for optimal power input and distribution. Still
it is necessary to observe certain criteria essential for application stability and reliability.
The table below indicates the absolute maximum input voltage ratings that must not be exceed-
ed. Power supplies to be used with the CP3002 should be carefully tested to ensure compli-
ance with these ratings.
The following table specifies the ranges for the different input power voltages within which the
board is functional. The CP3002 is not guaranteed to function if the board is operated beyond
the prescribed limits.
Table 5-1:
Maximum Input Power Voltage Limits
SUPPLY VOLTAGE
MAXIMUM PERMITTED VOLTAGE
+3.3 V
+3.6 V
+5 V
+5.5 V
+5 V STDBY (optional)
+5.5 V
Warning!
The maximum permitted voltages indicated in the table above must not be
exceeded. Failure to comply with the above may result in damage to your
board.
Table 5-2:
DC Operational Input Voltage Ranges
INPUT SUPPLY VOLTAGE
ABSOLUTE RANGE
RECOMMENDED RANGE
+3.3 V
3.2 V min. to 3.47 V max.
3.3 V min. to 3.47 V max.
+5 V
4.85 V min. to 5.25 V max.
5.0 V min. to 5.25 V max.
+5 V STDBY (optional)
4.85 V min. to 5.25 V max.
5.0 V min. to 5.25 V max.
Содержание CP3002
Страница 12: ...Preface CP3002 Page xii ID 1042 9252 Rev 2 0 P R E L I M I N A R Y This page has been intentionally left blank...
Страница 20: ...Preface CP3002 Page xx ID 1042 9252 Rev 2 0 P R E L I M I N A R Y This page has been intentionally left blank...
Страница 21: ...CP3002 Introduction ID 1042 9252 Rev 2 0 Page 1 1 Introduction Chapter 1 1 P R E L I M I N A R Y...
Страница 69: ...CP3002 Installation ID 1042 9252 Rev 2 0 Page 3 1 Installation Chapter 1 3 P R E L I M I N A R Y...
Страница 81: ...CP3002 Configuration ID 1042 9252 Rev 2 0 Page 4 1 Configuration Chapter 1 4 P R E L I M I N A R Y...
Страница 100: ...Configuration CP3002 Page 4 20 ID 1042 9252 Rev 2 0 P R E L I M I N A R Y This page has been intentionally left blank...
Страница 101: ...CP3002 Power Considerations ID 1042 9252 Rev 2 0 Page 5 1 Power Considerations Chapter 1 5 P R E L I M I N A R Y...
Страница 109: ...CP3002 Thermal Considerations ID 1042 9252 Rev 2 0 Page 6 1 Thermal Considerations Chapter 1 6 P R E L I M I N A R Y...
Страница 119: ...CP3002 CP3002 HDD ID 1042 9252 Rev 2 0 Page A 1 CP3002 HDD Chapter 1 A P R E L I M I N A R Y...
Страница 120: ...CP3002 HDD CP3002 Page A 2 ID 1042 9252 Rev 2 0 P R E L I M I N A R Y This page has been intentionally left blank...
Страница 132: ...CP3002 HDD CP3002 Page A 14 ID 1042 9252 Rev 2 0 P R E L I M I N A R Y This page has been intentionally left blank...
Страница 133: ...CP3002 CP RIO3 04 Rear I O ID 1042 9252 Rev 2 0 Page B 1 CP RIO3 04 Appendix 1 B P R E L I M I N A R Y...
Страница 149: ...CP3002 SATA Flash Module ID 1042 9252 Rev 2 0 Page C 1 SATA Flash Module Appendix 1 C P R E L I M I N A R Y...
Страница 150: ...SATA Flash Module CP3002 Page C 2 ID 1042 9252 Rev 2 0 P R E L I M I N A R Y This page has been intentionally left blank...