4. Safety Instructions 

 

4.

 

 Safety Instructions 

 

 

Please read this section carefully and observe the instructions for your own safety and correct use of the device. 

The chapter also contains information on approval and interference suppression of your device. 

Observe the warnings and instructions on the device and in the manual. 

The M@CII system has been built and tested by Kontron Embedded Computers in accordance to  

IEC/EN/UL/CSA 60950 and left the company in a perfectly safe condition. 

In order to maintain this condition and ensure safe operation, the user must observe the instructions and warnings 

contained in this manual. 

 

The device must be used in accordance with the instructions for use. 

 

The electrical installations in the room must correspond to the requirements of the local (country-specific) regulations.  

 

Take care that there are no cables, particularly power cables, in areas where persons can trip over them. 

 

Do not use a power cable in sockets shared by a number of other power consumers. Do not use an extension cable. 

 

Only use the power cord supplied. Don’t use injured or damaged power cords. 

 

Hints for DC power connection: 

The DC power source should be able to be switched off and on via an isolating switch. 

The unit is only completely disconnected from the DC main power source, when the DC power cord is disconnected 

either from the power source or the unit. Therefore, the DC power cord and its connectors must always remain easily 

accessible. 

 

Hints for AC power connection via external AC/DC adapter: 

The main power cable of the optional external AC/DC adapter serves as disconnecting device. For this reason the 

outlet of the AC power source must be located near to the device and be easily accessible. 

 

Do not place the device in direct sunlight, near heat sources or in a damp place. Make sure the device has adequate 

ventilation. 

 

Only devices and components which fulfill the requirements of an SELV circuit (safety extra low voltage) in 

accordance with EN60950 may be connected to the interfaces of the system. 

 

All plugs on the connection cables must be screwed or locked to the housing. 

 

The M@C II system is designed to be used only in vertical position with the interfaces downwards. 

 

The device generates heat during operation. Make sure it is adequately ventilated. Do not cover the air intake and 

exhaust openings of the device. 

 

Repairs may only be carried out by qualified specialist personnel authorized by Kontron Embedded Computers. 

 

Maintenance or repair on the open device may only be carried out by qualified personnel authorized by Kontron 

Embedded Computers which is aware of with the associated dangers. 

 

The M@C II system may only be opened in accordance with the description in this user’s manual for: 

 Replacing of the Lithium battery 

 Configuration of the RS422/RS485 interface. 

These procedures have to be carried-out only by qualified specialist personnel. 

 

When accessing internal components the device must be switched off and disconnected from the power source. 

 

Only approved original accessories (optional parts) approved by Kontron Embedded Computers may be used. 

 

The DC-input must fulfill SELV requirements of EN60950-1 standard. 

 

The chassis of the M@C II system must be protective earthed by establishing a large-area contact between the 

earth screw (at the rear bottom side) and an appropriate grounding connection point. 

 

It must be assumed that safe operation is no longer possible, 

 if the device has visible damage or 

 if the device no longer functions. 

In these cases the device must be shut down and secured against unintentional operation. 

M@CII 70/104/121/150 - User’s Manual (V1.00) 

Содержание 2-A0HC Series

Страница 1: ......

Страница 2: ...This page intentionally left blank...

Страница 3: ...d Cleaning 17 6 2 Bottom View 18 6 2 1 Power Control Indicator Reset and Grounding 19 6 2 2 Interfaces Rear Bottom Side of the System 21 6 2 3 Optional Interfaces 22 6 3 Top View 24 6 3 1 CompactFlash...

Страница 4: ...7 8 1 1 Ethernet Interfaces LAN1 and LAN2 47 8 1 2 USB Interfaces USB 47 8 1 3 Serial Port RS232 COM1 COM2 47 8 1 4 Serial Port RS422 RS485 configured as RS422 4 Channel Mode 48 8 1 5 Serial Port RS42...

Страница 5: ...reason Kontron Embedded Computers expressly informs the user that this manual only contains a general description of technical processes and instructions which may not be applicable in every individu...

Страница 6: ...specific product configuration This symbol precedes helpful hints and tips for daily use Microsoft MS DOS Windows 98 Windows 2000 Windows CE net Windows XP are registered trademarks of the Microsoft...

Страница 7: ...eyond that provided by law This applies to batteries to the display backlighting for example 3 2 Exclusion of Accident Liability Obligation Kontron Embedded Computers shall be exempted from the statut...

Страница 8: ...accessible Do not place the device in direct sunlight near heat sources or in a damp place Make sure the device has adequate ventilation Only devices and components which fulfill the requirements of a...

Страница 9: ...ectrostatic sensitive components PCB s and assemblies by the case or the edge of the board 4 Avoid contact with pins leads or circuitry 5 Turn off power and input signals before inserting and removing...

Страница 10: ...ons Operation of this equipment in residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense English This Class A...

Страница 11: ...al Mounting Plate VESA 75 compliant for M CII 70 Mounting Plate VESA 75 100 compliant for M CII 104 121 150 5 2 Type Label and Product Identification System Type Product Designation Product Identifica...

Страница 12: ...optionally The power LED marked PWR and the RESET button are located on the bottom side of the M CII system interface side Interfaces such as 1x serial COM1 RS232 2x LAN 10 100 Mbps 2x USB 2 0 1x VGA...

Страница 13: ...1 Bottom view Fig 2 Right view Fig 3 Frontal view Fig 4 Left view Fig 5 Top view Fig 6 Rear view In these pictures Fig 1 up to Fig 7 the M CII system is shown as an M CII 104 unit M CII 70 104 121 15...

Страница 14: ...ss to glass technology 3 Covered USB interface 1 2 Fig 8 Frontal view of the M CII 70 system 1 Front plate 2 7 TFT display with touch screen glass to glass technology The USB interface connector is av...

Страница 15: ...70x10 90 inch 380x312 mm 14 96x12 28 inch 449 4x354 mm 17 69x13 93 inch Frontal cut out for display WxH 157x95 8 mm 6 18x3 77 inch 214 2x161 2 mm 8 43x6 34 inch 248x186 5 mm 9 76x7 34 inch 306x230 mm...

Страница 16: ...een s image or may be unnecessarily small in size If necessary in order to access the calibration routine use an USB mouse 6 1 4 1 Calibrate the Touch Screen for Windows XP The touch screen of your M...

Страница 17: ...ration Fig 12 Calibration acc selected calibration points and offset For more information about touch screen calibration you find in the Hampshire TSHARC UniWinDriver Users Manual for Windows XP on th...

Страница 18: ...RC touch screen calibration tool linked on desktop Run the calibration routine when an alignment problem exists between the mouse pointer and the stylus contact location on the screen You can adjust t...

Страница 19: ...ch screen surface is subject to burning and scaring from direct heat sources such as cigarettes The display front is sealed against dust liquids etc The front surface of the touch screen is a flexible...

Страница 20: ...ton 8 Power LED control indicator PWR 9 Grounding screw with lock washers 10 Front panel of the system with seal at the rear side 11 Two pairs mounting slots two pairs on each side of the display s re...

Страница 21: ...121 150 detail for Power LED and Reset button on the bottom rear side 1 Power LED PWR located on the bottom rear side of the M CII 70 104 121 150 system 2 Reset button on the bottom rear side of the...

Страница 22: ...main memory will be erased The RESET button can be accessed only with a small pointed object 6 2 1 4 Grounding Screw M4 with lock Washers The chassis of the M CII 70 104 121 150 system must be grounde...

Страница 23: ...d as RJ45 sockets with integrated LEDs Ethernet Port Data Transfer Rate LAN1 10 100 Mbps LAN2 10 100 Mbps Ethernet LED States Left LED State Link Activity State Right LED State Link Speed off Link not...

Страница 24: ...e done automatically The user can determine if the automatic mode switch to transmission mode should be triggered by the RTS line or should be triggered by the last sent message using the TxD line If...

Страница 25: ...FF ON OFF 8 4ms OFF OFF ON ON 7 8ms OFF ON OFF OFF 7 2ms OFF ON OFF ON 6 5ms OFF ON ON OFF 5 9ms OFF ON ON ON 4 8ms 2400 ON OFF OFF OFF 4 3ms ON OFF OFF ON 3 7ms ON OFF ON OFF 3 1ms ON OFF ON ON 2 5ms...

Страница 26: ...terface and top side When powering on the M CII 70 104 121 150 system make sure that the air intake and exhaust openings are not obstructed 6 3 1 CompactFlash Slot The system is equipped with a Compac...

Страница 27: ...g 25 Fig 26 and Fig 27 1 Front panel of the system with seal at the rear side 2 Enclosure of the display 3 System cover 4 Mounting slots with installed mounting clamp and Allen Screw 5 Screws that sec...

Страница 28: ...m with seal at the rear side 2 Mounting clamp and Allen Screw for mounting to a subframe 3 Threaded hole marked red in the picture only 4x for mounting the VESA 75 100 compliant adapter plate refer to...

Страница 29: ...he M CII 121 into a subframe or panel M CII 70 104 121 150 User s Manual V1 00 27 6 4 1 9 10 3 3 5 11 11 11 11 11 3 11 Fig 30 Rear side of the system shown as a M CII 121 system The M CII system can b...

Страница 30: ...28 and Fig 29 with four M4x6 metric screws Do not use longer screws than the original screws provided M4x6 metric Using longer screws damage the internal components of the system Fig 31 Rear and botto...

Страница 31: ...res may not exceed 10 m M CII 70 104 121 150 User s Manual V1 00 29 2 3 4 6 5 1 Fig 33 Phoenix plug terminal with plus and minus marking M CII 70 104 121 150 1 3 pin Phoenix plug terminal 2 Cover over...

Страница 32: ...acle DC Power Wires marked plus and minus via included power plug terminal to the system AC Power Connector Power LED AC DC Adapter Fig 34 Optional external AC DC adapter not included AC DC Adapter AC...

Страница 33: ...settings of the SW1 DIP1 DIP8 proceed as follows The new port configuration has to be set before the system is installed on a panel or into an industrial cabinet The system must be disconnected from t...

Страница 34: ...inal face up Gently push the battery into the holder in as far as it goes 4 Make sure that you insert the battery correctly The plus pole must be on top 5 Close the unit as described in the chapter 6...

Страница 35: ...C power connector of the system is on the rear bottom side and is labeled 24V DC Make sure the connector is securely locked in place 2 Ensure that the DC power source is switched off via an isolating...

Страница 36: ...is securely locked in place 2 Connect the AC power cord to the AC DC adapter 3 Plug the AC connector of the adapter into an AC wall outlet of the AC power source Behaviour of the M CII 70 104 121 150...

Страница 37: ...r the Installation of the Hampshire TSHARC Touch Screen Controller Driver 6 10 1 1 Preparations of System for Installation Procedure Before installing the driver please check the following items opera...

Страница 38: ...I 150 into a subframe panel The mounting clamps with screws supplied allow the easy and fast mounting of the M CII 70 104 150 into an instrument panel or wall panel Dimension for M CII 70 M CII 104 M...

Страница 39: ...Allen Screw s included 2 Depending on the dimension of the display enclosure of your system cut a hole in the panel subframe refer to Fig 41 or Table 6 for the panel cut out dimensions The panel where...

Страница 40: ...plate refer to Fig 30 pos 11 Please observe that this unit is designed as the panelmount version of the M CII system For the M CII 121 mounting cut a window and eight pre drill holes according Fig 42...

Страница 41: ...ve analog ETX PM 600 Module ETX LX 800 Module 5 5 5 5 ETX PM Module with Intel Celeron M ULV up to 1000 MHz Processor 5 5 5 Lithium Battery Type CR2032 UL listed 5 5 5 5 Reset Button RESET 5 5 5 5 Pow...

Страница 42: ...r Terminal 3 Pin 1x 1x 1x 1x Mounting Clamps for one screw 4x 8x Mounting Clamps for 2 screws 8x Screw for Mounting Clamps 4x 8x 16x Optional Parts VESA 75 compliant Mounting Plate 5 VESA 75 100 compl...

Страница 43: ...3 0 A 7 2 Environmental Specifications Thermal Management passive cooling for CPU and system Operating Temperature relative Humidity 0 50 C 20 90 non condensing 32 122 F 20 90 non condensing Storage T...

Страница 44: ...35 mm 9 25 348 mm 13 701 380 mm 14 96 449 4 mm 17 661 Depth total 50 3 mm 1 98 49 6 mm 1 953 57 1 mm 2 248 55 6 mm 2 189 Depth without front plate 47 3 mm 1 86 45 6 mm 1 795 51 1 mm 2 012 51 6 mm 2 03...

Страница 45: ...7 Technical Data Fig 45 Frontal view of the M CII 121 system Fig 46 Frontal view of the M CII 150 system M CII 70 104 121 150 User s Manual V1 00 43...

Страница 46: ...7 Technical Data M CII 70 left side view M CII 104 left side view M CII 121 left side view M CII 121 rear view M CII 104 rear view M CII 70 rear view 44 M CII 70 104 121 150 User s Manual V1 00...

Страница 47: ...7 Technical Data M CII 70 104 121 150 User s Manual V1 00 45 M CII 150 left side view M CII 150 rear view...

Страница 48: ...ent 16 A per phase EN 61000 3 3 2006 Limitation of voltage changes voltage fluctuations and flicker in public low voltage supply systems for equipment with rated current 16 A per phase and not subject...

Страница 49: ...yellow 10 100 1 8 8 1 2 USB Interfaces USB Pin Signal Name 4 pin USB Socket Type A Version 2 0 1 1 1 VCC 2 Data 3 Data 4 GND 8 1 3 Serial Port RS232 COM1 COM2 Pin Signal Name 9 pin D SUB Plug male 1...

Страница 50: ...D Receive Data 5 GND Signal Ground 6 RTS Request to Send 7 RTS Request to Send 8 CTS Clear to Send 9 CTS Clear to Send 8 1 5 Serial Port RS422 RS485 configured as RS485 4 Wire Mode full duplex Bus Mas...

Страница 51: ...ta 4 NC 5 GND Signal Ground 6 NC 7 NC 8 NC 9 NC 8 1 7 VGA Port VGA Pin Signal Name 15 pin D SUB Connector female 1 Analog red output 2 Analog green output 3 Analog blue output 4 N C 5 8 GND 9 5 V DDC...

Страница 52: ...w kontron com or by writing to Kontron Embedded Computers GmbH Oskar von Miller Str 1 85386 Eching Germany 9 1 Returning Defective Merchandise Before returning any merchandise please 1 Contact our Ser...