22
454200/A
9
Once the door is stable in the tilted position, select
Tilted
.
10
Select
Set
to accept the values.
We recommend you to write down the relevant values for each door, in case you
need them when you change doors or sensors.
11
Disconnect the sensor from the interface cable and the computer.
Manually entering the known pitch and roll
calibration values of a sensor on the trawl
door
If you need to replace a door mounted sensor, you can enter the known calibration values
from the old sensor by means of the TV80 without performing a new calibration.
Procedure
1
Connect the sensor to a computer running the TV80 and/or PX Configurator
programs with a dedicated cable.
2
On the processor unit desktop, double-click the relevant program icon to start it.
3
Open the
Setup
menu.
4
On the
Setup
menu, select
Installation
.
Observe that the
Installation
dialog box opens.
5
At the bottom of the
Sensor list
page, select
Add New Sensor
.
The
Add New Sensor
dialog box opens.
6
Select
Yes
.
7
In the very first
PX Sensor Configurator
dialog box, select communication port
and sensor type, then select
Connect
.
The relevant sensor
Configurator
dialog box opens.
8
Select
Calibrate Sensor
to open the dialog box.
9
Enter the known values in
Door Installation Offsets
.
If you are using the calibration values of a PX MultiSensor Mk1 on a PX
MultiSensor Mk2, you must on a port door sensor switch the sign on roll value and
on the starboard sensor switch sign on Yaw value.
10
Select
Set
to accept the values.
11
Disconnect the sensor from the interface cable and the computer.
Simrad PX MultiSensor Mk2 Instruction Manual