E-64
Displaying the Measurement Results
At the end of measurement, the measurement results will be displayed on the LCD according to the spec-
ified measurement condition. Typical measurement result screens are shown hereafter. To change LCD’s
display contents, change them in the corresponding <COND
*
> screen. For details, refer to “Setting a
Measurement Condition” (from page E-34).
Measured Data
The following screen appears if “DIFF&ABS” has been selected for “DISPLAY” mode.
N
ote
• Color difference will not be displayed if no target color has been selected.
• If the target mode is “linked to each data.”, you will not be able to view the color difference for measurement
data that uses the deleted color difference target data.
M
emo
“#####” will be displayed if the color difference data has two or more decimal places.
1
Ready to measure.
2
Currently selected <COND
*
> no.
3
Mask/gloss/UV at the time of measurement
4
Currently selected observer/illuminant
5
Currently selected measured data no.
6
Currently selected target color data no.
7
Measured data
8
Measurement date. For the year, only the lower two digits are displayed.
9
Displays the relative gloss value. If the gloss value exceeds 200, the screen will display
“G###” in place of the value.
0
Deletes the currently displayed measured data.
A
Displays other measured data.
B
Switches the screen page from one to another (when there are two pages or more).
C
Switches to the <TARGET> screen for the currently selected no. (T
*
).
D
Outputs the currently displayed measured data to the printer.
E
Returns to the <COND
*
> screen.
F
Appears if there is insufficient battery power when the instrument is powered by the bat-
tery. If
appears, replace the batteries with new ones.
Содержание CM-2600d
Страница 1: ...Spectrophotometer CM 2600d 2500d E Instruction Manual Es Manual de instrucciones...
Страница 11: ...E 9 Chapter 1 Before Using the Instrument...
Страница 27: ...E 25 Chapter 2 Preparation for Measurement...
Страница 62: ...E 60 Setting Color Difference Tolerances...
Страница 63: ...E 61 Chapter 3 Measurement...
Страница 79: ...E 77 Chapter 4 Other Functions...
Страница 108: ...E 106 TASK Mode...
Страница 109: ...E 107 Chapter 5 Troubleshooting...
Страница 114: ...E 112 Troubleshooting...
Страница 115: ...E 113 Chapter 6 Appendix...
Страница 122: ...E 120 Dimensions Dimensions 193 96 96 69 mm The measurement area selector is not available with the CM 2500d...
Страница 123: ...E 121 Dimensions...
Страница 126: ......
Страница 127: ...E Es 2002 2005 KONICA MINOLTA SENSING INC AFMAGA 1 Printed in Japan 9222 1856 40...