Chapter 4 Confirming Operation Using Service Tool
4-6
4.3
Confirming Operation for Each Unit
Procedure to confirm the operation is explained here using stand-alone action of the receiver motor.
1
Click the [Pulse Motor] in the [Unit Test] screen.
[Pulse Motor] panel is displayed.
2
Select the cassette size to be emulated from the
[Cassette Type].
3
Click the [Initialization] button for the receiver
motor.
Initialization of the receiver mechanism is performed.
Initialization here is to move other mechanism so it will
be possible to operate the receiver.
Once the initialization is completed, [Move to HP]
button is enabled. Also, a message [Initialization ... OK]
is displayed in the [Information] area saying that the
initialization has finished without any problem.
Caution
Do not use the cassette for confirming operation for each unit (except for "Adjustment" and
"Monitoring" panels).
To perform confirmation using the cassette, perform the confirming by step operation. See
Confirming by Step Operation (Page 4-8)"
for confirming by step operation.
Note
Only the [Initialization] button is available for each motor in the [Pulse Motor] panel when it is
first displayed.
Buttons to move to available positions will be enabled once the initialization is performed for
each motor. Every time the motor is moved, available position will change, and only applicable
buttons will be enabled. [Initialization] button will be enabled regardless of the position.
Note
When the [Cassette Type] is changed, only
[Initialization] button will be enabled like
when the panel was switched.
Содержание 0902
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 30: ...2 10...
Страница 54: ......
Страница 84: ...Chapter 3 Troubleshooting 3 30 3 2 19 Confirm the H sync Signal To be stated...
Страница 85: ...Chapter 3 Troubleshooting 3 31 3 2 20 Confirm the LMC Operation To be stated...
Страница 120: ......
Страница 296: ...8 10...
Страница 300: ......
Страница 301: ......