381298/C
175
a
If the cable has already been installed in conduits, measure the maximum
length of cable required to reach from the final cable clip outside the cabinet to
the terminal blocks inside the cabinet, add 20 cm, then remove the excess cable.
b
If the cable has not been installed in conduits, measure the maximum length of
wire required to reach from the cable gland to the terminal blocks inside the
cabinet, add 20 cm, and mark the cable.
Note
The cable’s outer insulation will extend into the cable gland to a point approximately
5 mm outside the outer surface of the cabinet wall into which the cable gland is
secured.
4
Carefully remove the outer insulation from the required cable length.
Be careful to avoid damage to the screening!
5
Leaving an appropriate length of the screen exposed from the insulation, cut off
the remainder.
Securing and terminating cables
Once a cable has been prepared for termination, it must be connected to a unit or cabinet.
Prerequisites
Electrical installations can only be done by certified electricians. All necessary tools and
instruments required must be available. The installation shipyard must prepare detailed
drawings of the electrical system, and identify each cable.
Context
Observe the relevant cable plan and/or interconnection drawing(s) for the product.
Procedure
1
Referring to the wiring diagram and ensuring that there is 5 to 10 cm slack cable
inside the cabinet, prepare and connect the cable cores to the appropriate terminals
and/or plugs within or onto the cabinet.
2
Secure the cable using cable clips.
3
Check the terminal connections against the wiring diagram to ensure they are
correct. Follow the same procedure for all the cables and cable glands.
4
Check the cabinet to ensure all tools and rubbish are removed, then close the
cabinet door.
5
Take the appropriate safety measures, then replace the fuses and apply power to
the system.
6
Perform a relevant system test to ensure the installation has been made successfully.
Содержание Simrad SN90
Страница 2: ......
Страница 117: ...381298 C 115 Related topics Installation summary page 65 Installing the transducer ...
Страница 226: ...224 381298 C 427 385 All measurements in mm The drawing is not in scale 385609 Rev B CD12_385609_001_002 Simrad SN90 ...
Страница 236: ...234 381298 C 372915 Clamping frame Simrad SN90 ...
Страница 295: ......
Страница 296: ... 2016Kongsberg Maritime ISBN 978 82 8066 179 1 ...
Страница 297: ......