162
381298/C
Communication and power cable for the Operating Panel
A dedicated serial line cable is used to connect the Operating Panel to the Processor Unit.
(CD0806_101_005 / 860-202102)
P2(2)-R
P3(5)-WH
P3(2)-R
P2(5)-WH
P2(3)-BL
P3(1)-GN
P3(8)-BL
P3(7)-BK
P3(6)-YE
P4(1)-BL
P4(3)-WH
P4(2)-R
Pin 1
Pin 1
Pin 1
P4(9)-R
P4(4)-WH
P4(10)-GN
P4(14)-BK
P4(15)-BL
P4(13)-YE
A
15–pin D-connector, female, connects to the bottom of the Operating Panel.
B
9–pin D-connector, female, connects to the rear side of the Processor Unit.
C
9–pin D-connector, male, connects to the rear side of the Processor Unit.
(All connectors are seen from the solder side.)
This length of this cable is approximately three meters. The order number is 380–202101.
Note
The length of this cable must not be extended.
Minimum cable requirements
Not applicable. This cable is provided with the SN90 delivery.
Related topics
Connecting the dual cable between the Operating Panel and the Processor Unit, page 146
Simrad SN90