416739/A
65
Installing the Wideband Transceiver (WBT)
using the integrated brackets
The ES80 Wideband Transceiver (WBT) is normally positioned in a dedicated room in the
vicinity of the transducer. The physical length of the cables limit the distance between each
transducer and the Wideband Transceiver (WBT). The Wideband Transceiver (WBT) can
be installed vertically or horizontally using the integrated mounting brackets. Four bolts
are used, two on each side.
Prerequisites
A suitable location for the Wideband Transceiver (WBT) must be defined prior to
installation. It is normally positioned in the sonar room close to the transducer. The unit
can in principle be mounted anywhere on board the ship, provided that the location is dry
and ventilated.
The length of the transducer cables limits where the Wideband Transceiver (WBT) can be
installed.
You must be equipped with a standard set of tools. This tool set must comprise the normal
tools for electronic and electromechanical tasks. This includes different screwdriver types,
pliers, spanners, a cable stripper, a soldering iron, etc. Each tool must be provided in various
sizes. We recommend that all tools are demagnetized to protect your equipment.
Context
The unit can be mounted in any direction and on any
surface provided that the environmental requirements
are met.
Note
If you mount the unit on a bulkhead, position it so that all
the sockets are facing down.
These points must all be considered to reduce electrical noise on an ES80 system.
• If you more than one Wideband Transceiver (WBT), install these in such a way that the
transducer cables have the maximum distance to the power and Ethernet cables.
• Ensure maximum physical distance between the Wideband Transceiver (WBT) and
the Power Supply Unit.
• Ensure maximum physical distance between each Power Supply Unit.
• If possible, install the transceivers in a sonar room that is electrically shielded.
• Make sure that all units are properly grounded.
Содержание Simrad ES80
Страница 1: ...kongsberg com simrad Simrad ES80 INSTALLATION MANUAL ...
Страница 2: ......
Страница 25: ...416739 A 23 Related topics Scope of supply page 21 Simrad ES80 page 11 Simrad ES80 ...
Страница 278: ...276 416739 A 201575 Transducer connector assembly and wiring Simrad ES80 Installation Manual ...
Страница 309: ......
Страница 310: ... 2020 Kongsberg Maritime ISBN 978 82 8066 187 6 ...
Страница 311: ......
Страница 312: ...Installation Manual Simrad ES80 ...