416739/A
149
b
If the cable has not been installed in conduits: Measure the maximum length of
wire required to reach from the cable gland to the terminal block(s) inside the
cabinet. Add 20 cm, and mark the cable.
Note
The outer insulation on the cable will extend into the cable gland to a point
approximately 5 mm outside the outer surface of the cabinet wall.
4
Carefully remove the outer insulation from the required cable length.
Be careful! Do not damage the screen!
5
Leaving an appropriate length of the screen exposed from the insulation, cut off the
remainder.
Related topics
Basic cable requirements, page 143
Cable glands and termination procedures, page 147
Cable layout and interconnections, page 79
Securing and terminating cables
Once a cable has been prepared for termination, it must be connected to a unit or cabinet.
Prerequisites
Electrical installations can only be done by certified electricians. All necessary tools and
instruments required must be available. The installation shipyard must prepare detailed
drawings of the electrical system, and identify each cable.
Context
Observe the relevant cable plans, cable lists and/or interconnection drawings for the ES80.
Procedure
1
Referring to the wiring diagram and ensuring that there is 5 to 10 cm slack cable inside
the cabinet, prepare and connect the cable cores to the appropriate terminals and/or
plugs within or onto the cabinet.
2
Secure the cable using cable clips.
3
Check the terminal connections against the wiring diagram to ensure they are correct.
Follow the same procedure for all the cables and cable glands.
4
Check the cabinet to ensure all tools and rubbish are removed, then close the cabinet
door.
Содержание Simrad ES80
Страница 1: ...kongsberg com simrad Simrad ES80 INSTALLATION MANUAL ...
Страница 2: ......
Страница 25: ...416739 A 23 Related topics Scope of supply page 21 Simrad ES80 page 11 Simrad ES80 ...
Страница 278: ...276 416739 A 201575 Transducer connector assembly and wiring Simrad ES80 Installation Manual ...
Страница 309: ......
Страница 310: ... 2020 Kongsberg Maritime ISBN 978 82 8066 187 6 ...
Страница 311: ......
Страница 312: ...Installation Manual Simrad ES80 ...