416739/A
127
K-Sync interface to generic RS-232 synchronization input
For transmission synchronization purposes, the K-Sync will interface a generic RS-232 serial
line communication port using the CTS (Clear To Send) and RTS (Request To Send) signals.
The synchronized product is connected to the IO Module inside the K-Sync Synchronizing
Unit. Each IO Module in the K-Sync Synchronizing Unit provides six connectors and a
configuration board for physical adjustments of the communication parameters.
Pin number
Signal
Signal description
1
Trigger Out
This signal is transmitted to the system that needs to be
synchronized. Trigger Out allows the system to transmit ("ping").
2
Ground
Mandatory! This ground is connected to pin 5 inside the IO
Module.
3
RTT
Ready to Transmit: Ready to Transmit (RTT) is a return signal
from the hydroacoustic system that is synchronized. The Ready
to Transmit (RTT) signal means that the hydroacoustic system is
ready for the next trigger.
4
Trigger In
This signal is received from the system that needs to be
synchronized. Trigger In is "active" while the system is
transmitting.
5
Ground
Mandatory! This ground is connected to pin 2 inside the IO
Module.
6
Not used
A
Local connection on the Processor Unit
B
Connections on the K-Sync IO Module
Содержание Simrad ES80
Страница 1: ...kongsberg com simrad Simrad ES80 INSTALLATION MANUAL ...
Страница 2: ......
Страница 25: ...416739 A 23 Related topics Scope of supply page 21 Simrad ES80 page 11 Simrad ES80 ...
Страница 278: ...276 416739 A 201575 Transducer connector assembly and wiring Simrad ES80 Installation Manual ...
Страница 309: ......
Страница 310: ... 2020 Kongsberg Maritime ISBN 978 82 8066 187 6 ...
Страница 311: ......
Страница 312: ...Installation Manual Simrad ES80 ...