Synchronization sequences
In many applications, the synchronisation interface is based on an RS-232 serial port.
When you connect two systems for synchronisation using Clear to Send (CTS) and
Request to Send (RTS), one system must set up as a "Master" and the other as a "Slave".
When the EK80 is "Master" in a system, the synchronization can either take place in
Free running
mode, or in
Wait for slave
mode.
Slave
mode
When the EK80 is set up in
Slave
mode, it must receive a trigger signal from a peripheral
system every time the EK80 is going to transmit. This trigger signal is connected to a
serial port on the Processor Unit, and the
Clear To Send (CTS)
pin is used to give the
EK80 an "event" message. The message is processed by the EK80 software, and it will
(if the previous ping has been finished) start the ping sequence.
As an acknowledgement to the synchronization trigger, the EK80 sets the
Ready To Send
(RTS)
signal to a logic "low" before transmitting. This indicates that the EK80 is "busy".
Once the transmission and reception sequence ends, the EK80 sets the
Ready To Send
(RTS)
signal to a logic "high" to indicate that it is ready for the next ping.
Master
mode
When the EK80 is "Master" in a system, the synchronization can either take place in
Free running
mode, or in
Wait for slave
mode.
• Synchronization in
Free running
mode
When in
Free running
mode, the EK80 will ping as fast as possible, setting its Ready
to Send (RTS) signal to a logic "high" at start of each ping, and back to logic "low”
at the end of the ping. The "Slave" system is triggered the when the Ready to Send
(RTS) signal goes from "low" to "high".
• Synchronization in
Wait for slave
mode
When in
Wait for slave
mode, the EK80 will wait for a logic "high" Clear to Send
(CTS) signal from the "Slave" system before it starts a new ping sequence. This is the
"ready to ping" acknowledge from the "Slave" system.
Note
If you use the EK80 as "Master" to control two "Slave" systems, you must connect a
single cable (plus ground) from the Ready to Send (RTS) output on the Master system to
the Clear to Send (CTS) input on both "Slave" systems. The return from the Ready to
Send (RTS) outputs on the "Slave" systems can not be connected.
Related topics
Setting up the EK80 in a synchronized system, page 126
Cable layout and interconnections, page 85
Simrad EK80 Installation Manual
Содержание Simrad EK80
Страница 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Страница 2: ......
Страница 12: ...10 394149 D Simrad EK80 ...
Страница 223: ...394149 D 221 6 Start the installation by selecting Next 7 Select Finish to close the wizard Setting to work ...
Страница 313: ...394149 D 311 Drawing file ...
Страница 314: ...312 394149 D Simrad EK80 Installation Manual ...
Страница 317: ...394149 D 315 Drawing file ...
Страница 318: ...316 394149 D Simrad EK80 Installation Manual ...
Страница 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Страница 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Страница 353: ......
Страница 354: ...Installation Manual Simrad EK80 ...