108
394149/D
A
The junction box is isolated
from vessel ground.
B
Cable gland
C
Terminal block
D
Cable
E
Cable screen (Do not connect
the cable screen to vessel
ground.)
Procedure
1
Mount the junction box in a
suitable location.
2
Terminate the steel conduits
containing the transducer cable
as close to the junction box as
possible.
3
Make sure that the junction
box chassis is not connected
to vessel ground.
Use additional insulation if this is necessary to isolate the junction box completely.
4
Remove the insulation from the transducer cable. Connect the individual wires
to the terminal block.
5
Remove the insulation from the extension cable. Connect the individual wires
to the terminal block.
6
Make sure that you have connected the wires 1:1, and that the colours match.
7
Connect the cable screens to the cable glands in the junction box.
Related topics
Splicing the transducer cable, page 107
Cable layout and interconnections, page 85
Splicing the cable using a grounded junction box
Do not solder the wires together using only electrical tape for insulation. This will result
in electrical noise and reduced operational performance.
Simrad EK80 Installation Manual
Содержание Simrad EK80
Страница 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Страница 2: ......
Страница 12: ...10 394149 D Simrad EK80 ...
Страница 223: ...394149 D 221 6 Start the installation by selecting Next 7 Select Finish to close the wizard Setting to work ...
Страница 313: ...394149 D 311 Drawing file ...
Страница 314: ...312 394149 D Simrad EK80 Installation Manual ...
Страница 317: ...394149 D 315 Drawing file ...
Страница 318: ...316 394149 D Simrad EK80 Installation Manual ...
Страница 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Страница 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Страница 353: ......
Страница 354: ...Installation Manual Simrad EK80 ...