484164/A
79
Connecting to a 12-pin Amphenol socket
The transducer is connected to terminals
A
through
N
on a circular 12-pin Amphenol socket
(Type 97-12-19S). This socket is used on the General Purpose Transceiver (GPT), and on
several versions of the Wide Band Transceiver (WBT).
Beam
Cable colours
Terminal on socket
Transceiver channel
White
H
1
Black
J
1
Green
E
2
Black
F
2
Yellow
C
3
Black
D
3
Blue
A
Single-beam
Black
B
Single-beam
Digital output
Red
L
Not used
Digital ground
Black
M
Not used
Cable screen
Screen
N
Not applicable
The cable screen must be connected to the housing on the transducer plug.
Note
The black wires in the transducer cable are not for grounding. You must never connect these
together. You must never connect any of them to vessel ground.
We strongly recommend that you install the transducer cable in a steel conduit.
Содержание Simrad CP200-5C
Страница 1: ...Photo by Gatis Marcinkevics kongsberg com simrad Simrad CP200 5C INSTALLATION MANUAL ...
Страница 2: ......
Страница 55: ...484164 A 53 Related topics Preparations page 22 Acoustic noise page 45 Preparations ...
Страница 58: ...56 484164 A Related topics Preparations page 22 Simrad CP200 5C Installation Manual ...
Страница 99: ...484164 A 97 Related topics Installing the transducer page 57 Drawing file page 94 Drawing file ...
Страница 101: ...484164 A 99 Drawing file ...
Страница 102: ...100 484164 A Related topics Installing the transducer page 57 Drawing file page 94 Simrad CP200 5C Installation Manual ...
Страница 104: ...102 484164 A Related topics Installing the transducer page 57 Drawing file page 94 Simrad CP200 5C Installation Manual ...
Страница 110: ... 2022 Kongsberg Maritime ...