IS15 Wind Manual
22
20220752H
6.
When the wand is correctly in position,
screw down the
collar
until it is HAND tight
(2).
7.
Lock the retaining clip into place (3).
Note !
Remove the wand in the reverse order.
8.
The cable is easily threaded down the mast if a pull-through
cord or mouse has been left for that purpose. If there is no
mouse, it may help to fix a weight to the end of the cable to
assist its passage through the mast.
9.
If there is a small error in the alignment of the masthead
unit, this can be compensated for. Please refer to the
relevant calibration instructions for more details.
Note !
The masthead bracket includes an integral weatherproof cap that should
always be fitted to the socket if the wand has been removed.
5.4 Cabling
Stand Alone system (W-1)
Wind
Transducer
IS15 Wind
SIMRAD
Junction box (mast foot)
Supply 10,8-15,6VDC
10m (33')
30m (99')
Speed/heading
input on NMEA
Circuit breaker
*
**
Roblink cable with connector
(Special) Roblink Power Cable
*
**
Fuse 2A
Figure 5-3 W-1 IS15 Wind System