Replacement of Limit Switches in Feedback Units
1.
Switch off the main power supply to Motor Controller by turning off the S1 isolating switch.
2.
Remove the cover on the feedback unit.
3.
Identify the defective limit switch [2].
4.
Loosen the screws [1] on top of the switch assembly.
5.
Using a soldering iron, release the wiring from the switch.
6.
Solder the wiring to the new limit switch.
7.
Tighten the screws [1] on top of the switch assembly.
8.
Switch on the power by turning the S1 isolation switch inside the motor controller.
9.
Adjust the limit switch as detailed in chapter
11.16 Adjustment of Limit Switches in Feedback
10.
Install the cover on the feedback unit.