![Kongsberg M3 Sonar Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/kongsberg/m3-sonar/m3-sonar_reference-manual_1992642035.webp)
922-20297001/1.2
33
Choosing the sonar range
The
Range
function allows you to specify the maximum theoretical vertical depth and
horizontal distance covered by the M3 Sonar FLS.
Context
The M3 Sonar FLS Sonar Head can operate at different predefined near and far
ranges.
The range value is defined from the Sonar Head.
Note
You cannot change the range until the Sonar Head is connected. Right-clicking
in the sonar view and the range slider bar will both be disabled until the sonar
is running.
Procedure
1
Click
Setup
→
Connect
to start the Sonar Head.
2
Right-click inside the sonar view to display the range menu.
3
Select the desired near and far range from the menu.
Tip
You can change the units of measurement in the
Preferences
dialog box.
4
You can increase or decrease the range using the range slider bar to the
left of the sonar view.
Click the top arrows to increase or decrease the far range.