A standard commercial AC mains cable is used. The power cable is normally terminated
with an female IEC C13 inline socket. The AC mains end is terminated in an AC
connector suitable for the local standard and/or the output sockets on an uninterruptible
power supply (UPS). If this is not the case, you must replace the AC connector.
The typical cable length is between 1,5 and 2 meters. If this is too short you must use an
extension cable (not recommended), mount a new power outlet within range, or make
your own power cable with sufficient length. If you use an uninterruptible power supply
(UPS), you can also move the UPS to a different location within range.
Note
There are substantial differences between countries nomenclature related to power plugs
and sockets. Observe local standards and regulations.
Minimum cable requirements
•
Conductors
: 2 x 1.5 mm
2
+ 1.5 mm
2
Ground
•
Screen
: None
•
Voltage
: 750 V
•
Maximum outer diameter
: Defined by the plugs and/or the cable gland
Ground cable
Correct grounding is essential for safe operation and maximum performance.
A
Ground tag on unit
B
Vessel ground
The ground connection is made using a thick stranded (or
yellow/green) cable making a solid connection between
the cabinet and the bulkhead. It is normally provided with a
green/yellow colour. The grounding cable must be connected
to vessel ground in the fuse box, or other common grounding
point.
Minimum cable requirements
•
Conductors
: 1 x 6 mm
2
•
Screen
: None
•
Voltage
: 60 V
•
Maximum outer diameter
: Not applicable