Techniques for determine signal properties
Note
This step only needs to be performed for echo sounders where the signal properties are
not fully specified.
The signal characteristics of the trigger and the feedback signals can be determined
manually if not known. The information gathered during this step should be filled into
the Table Signal Overview
Signal interface overview, page 41
The length of the trigger cable affects the signal strength.
Use an oscilloscope for signal determination.
Prerequisites:
1
Open the K-Sync Application
Settings
→
Installation
→
Installation Settings
dialog
and click
Manage Installed systems
. Check the checkbox for the echo sounder you
want to configure and uncheck all other echo sounders.
If the echo sounder you want to configure is not available, see document 342435 -
K-Sync Operator Manual for echo sounder setup instructions.
2
Verify that the signals to be configured have been set up with the correct terminal
ID in the K-Sync Application
Installation Settings
dialog.
3
Enable the echo sounder being configured in the K-Sync application.
That is, the Enabled checkboxes in the Echo Sounder States area of the application
window should all be unchecked, except for the particular echo sounder being
configured.
4
Make sure that the hydro acoustic sensor that needs to be configured is assigned
to at least one
trigger group
.
In the main application window, under
Trigger group schedule
, click
Configure
to
assign the hydro acoustic sensor to a Trigger group .
5
The signal type (RS-232/TTL) must be set correctly for each core connection to the
I/O module.
KONGSBERG K-Sync Installation manual