134
922-20207001/1.0
Your images will be saved under the folder “C:\KML\Flexview_V0100\Images” by
default. You can change this save location through the
Preferences
dialog box.
A text file with information on the image capture sonar settings will also be created.
Tip
Open the
Preferences
dialog box to change the default save location, choose your own
filename, and add overlay text.
TVG Setup dialog box
When an acoustic pulse is sent through the water, it will gradually lose its energy. The
greater the distance between the Sonar Head and the target(s), the greater the loss of
energy.
TVG
(Time Variable Gain) compensates for the loss of acoustic energy due to
geometric spread and absorption.
How to open
Note
Each sonar application has its own TVG profile. Before changing the TVG settings, start
the sonar (click
Setup
→
Connect
), then select the sonar application you want to configure
from the
Sonar applications list
. The TVG profiles will not be saved when closing the
software — default values will apply when starting up the Flexview software.
Click the
TVG
button. This button is located on the tool bar.
Flexview Reference Manual
Содержание Flexview
Страница 1: ...Reference Manual Flexview Multibeam Sonar ...
Страница 2: ......
Страница 8: ...6 922 20207001 1 0 Flexview ...
Страница 159: ......
Страница 160: ... 2019 Kongsberg Mesotech ...