You can use the positioning function to move the rotator to a specific position (in
degrees). Use this function for precise and quick positioning instead of clicking
the
Go Up
or
Go Down
buttons. Enter a degree in the
To position
field, then click
Goto
(single-axis only). You can also rotate in degree increments by entering a
degree into the
Step by size
field, then clicking
Step Up
or
Step Down
to rotate to
the next/previous increment.
If you have a dual-axes rotator, you can enter a degree into the
Tilt to position
or
Pan to position
fields, then click the associated button to move the Sonar Head
to that position on the tilt or pan axis.
Click the
Stop Move
button to cancel the rotation.
Rotator Control Dialog Type
Set the
Rotator Control Dialog Type
before you start operation of the sonar.
Select
Pan/Tilt Control
if you wish to manually move the Sonar Head up, down, or
sideways during operation. The
3D Scan
option is not supported on the Flexview.
System Configuration dialog box - Master Reference page
On the
Master Reference
page, you can assign any external sensors you have set up as
the primary source for various types of navigational data.
How to open
This dialog box is opened from the
Setup
menu.
Select the
Deployment
→
Master Reference
tab.