922-20207001/1.0
143
Performance specifications
These performance specifications summarize the main functional and operational
characteristics of the Flexview system.
•
Range:
–
500 kHz
: 0.2 m to >150 m
–
950 kHz - 1400 kHz
: 0.2 m to 70 m
•
Coverage
: 140°
•
Range resolution
: 1 cm
•
Frequency
: Dependent on transducer
•
Pulse types
: CW, CHIRP
•
Modes
: Dependent on transducer
•
Communication
: Ethernet
•
Data Rates
: 10/100 Mbps
Synchronization
•
PRI Synchronization (master / slave operation):
–
Sync Input
: 0 to 5 VDC, hold-off when high
–
Sync Output
: 0 to 5VDC active low pulse 100μs
Imaging mode — 500 kHz
•
Horizontal Field of View
: 140°
•
Vertical Beamwidth
: 30°
•
Angular Resolution
: 1°
•
Update rate
: up to 40 Hz
eIQ mode — 500 kHz
•
Horizontal Field of View
: 140°
•
Vertical Beamwidth
: 30°
•
Angular Resolution
: 0.95°
•
Update rate
: up to 10 Hz
Imaging mode — 950 kHz
•
Horizontal Field of View
: 140°
•
Vertical Beamwidth
: 27°
•
Angular Resolution
: 0.8°
•
Update rate
: up to 40 Hz
Содержание Flexview
Страница 1: ...Reference Manual Flexview Multibeam Sonar ...
Страница 2: ......
Страница 8: ...6 922 20207001 1 0 Flexview ...
Страница 159: ......
Страница 160: ... 2019 Kongsberg Mesotech ...