116
922-20207001/1.0
Power User Settings XML file, page 124
Power User Settings dialog box
The
Power User Settings
dialog box allows you to configure advanced controls. You can
also override the beamlist or processing type during playback. The Ping Rate, Update
Rate, and Mode ID are displayed for your information.
How to open
This dialog box is opened from the
Advanced
menu.
Description
Use the Advanced Controls to configure special
processes used during beamforming. Use the
Playback Controls to override the fields of
recorded “.mmb” data during playback. You can
also view detailed system information for the
current sonar application.
Details
Advanced Controls
•
RX Amplitude and Phase Correction
This feature allows you to make sure the
RX Amplitude and Phase Correction has
been successfully written to the Sonar
Head during production configuration.
Unchecking this box will not apply the
correction stored in the Sonar Head to
the raw data before beamforming.
•
Azimuth Processing
This feature allows you to make sure
the raw data is received properly and to
make sure there are no faulty elements
in the transducer. Unchecking this box
will display the range-compressed raw
data in the sonar view with a range vs.
element number instead of a range vs.
beam angle. The beamforming processing (either the time-domain beamformer
or the FFT beamformer) will not be applied.