58
472405/A
Transducer cables and space requirement
The transducer cables connect the transducers to the Processing Unit.
The transducer cables are Ethernet cables fit with underwater connectors at the transducer
ends. In addition the TX cable provides power to the transmit transducer.
The receive transducer is powered from the transmit transducer via a The TX/RX
synchronization/power cable.
The minimum bending radius is the minimum radius you can bend the transducer cable
without damaging it.
A
•
Transmit Transducer cable
: Minimum bending radius: 125 mm
The connector and cable will with minimum bending radius build 215 mm.
•
Receive Transducer cable
: Minimum bending radius: 100 mm
The connector and cable will with minimum bending radius build 190 mm.
See
Cable layout and interconnections
for more cable details.
See
Handling of underwater connectors
for procedures for cleaning and lubrication of
underwater connectors.
Related topics
Cable drawings and specifications, page 108
Handling of underwater connectors, page 141
KONGSBERG EM 2040 MKII Installation Manual
Содержание EM 2040 MKII
Страница 8: ...8 472405 A KONGSBERG EM 2040 MKII...
Страница 92: ...92 472405 A Related topics List of cables page 101 KONGSBERG EM 2040 MKII Installation Manual...
Страница 107: ...472405 A 107 Related topics Cable plan Hydrographic Work Station page 100 Cable layout and interconnections...
Страница 177: ...472405 A 177 338208 RX transducer outline dimensions 0 7 degrees Drawing file...
Страница 178: ...178 472405 A 338207 TX transducer outline dimensions 0 7 degrees KONGSBERG EM 2040 MKII Installation Manual...
Страница 179: ...472405 A 179 337805 TX transducer outline dimensions 0 4 degrees Drawing file...
Страница 180: ...180 472405 A 353631 Transducer mounting plate 0 7 x 0 7 degrees KONGSBERG EM 2040 MKII Installation Manual...
Страница 181: ...472405 A 181 355913 Transducer mounting plate 0 4 x 0 7 degrees Drawing file...
Страница 182: ...182 472405 A 359252 Baffle plate 0 7 x 0 7 degrees KONGSBERG EM 2040 MKII Installation Manual...
Страница 183: ...472405 A 183 385422 Processing Unit dimensions Drawing file...
Страница 184: ...184 472405 A 424178 Portable Processing Unit dimensions KONGSBERG EM 2040 MKII Installation Manual...
Страница 185: ...472405 A 185 464618 HWS dimensions MC330 Rack model Drawing file...
Страница 186: ...186 472405 A 475694 HWS dimensions MC330 Desktop model KONGSBERG EM 2040 MKII Installation Manual...
Страница 187: ...472405 A 187 370275 Remote Control Unit K REM dimensions Drawing file...
Страница 188: ...188 472405 A 373962 Remote Control Unit K REM wiring diagram KONGSBERG EM 2040 MKII Installation Manual...
Страница 247: ......
Страница 248: ...2021 Kongsberg Maritime...