EM 122
Steel conduits
The transducer cables connect through the vessel’s hull using steel conduits welded to the
hull. The top of each conduit must be closed and sealed to preserve the watertightness.
This can be done with a “Bratberger”, “Roxtec” or a similar sort of sealing device.
The installation of the steel conduits must be properly planned, and all plans and
drawings must be approved by the vessel’s classification authority.
For the principles, see
EM 122 blister and steel pipe arrangements (example)
on page 25
The steel conduits must be designed to fit each individual vessel. They are not included
with the system delivery. The steel conduits must therefore be both provided (or
manufactured) and installed by the installation shipyard. The number of steel conduits
depends on the chosen system configuration and the internal diameter of the conduits.
• a 0.5° x 1° system (96 TX modules and 16 RX modules) requires four TX conduits
and one RX conduit.
• a 1° x 1° system (48 TX modules and 16 RX modules) requires two TX conduits
and one RX conduit.
• a 1° x 2° system (48 TX modules and 8 RX modules) requires two TX conduits
and one RX conduit.
• a 2° x 2° system (24 TX modules and 8 RX modules) requires one TX conduit and
one RX conduit.
• a 2° x 4° system (24 TX modules and 4 RX modules) requires one common TX
and RX conduit.
Logistics and references
Safety
- Refer to the general safety procedures.
Qualifications
- Mechanical workers
Ship location
- Dry dock
Special tools
- None
Drawings
on page 109
Procedure
How to mount the steel conduits
1
Design the steel conduits with appropriate length and diameter to fit the echo
sounder.
2
Mount the steel conduits from the vessel hull and up towards the sonar room and
the EM 122 Transceiver Unit.
• The RX steel conduit(s) should have an inner diameter of minimum 146 mm.
• The TX steel conduit(s) should have an inner diameter of minimum 197.0 mm.
26
317669/B
Содержание EM 122
Страница 1: ...EM 122 Multibeam echo sounder Installation Manual...
Страница 2: ......
Страница 13: ...EM 122 Figure 1 System diagram 317669 B 11...
Страница 26: ...EM 122 Figure 6 EM 122 Gondola example Cd021 107 24 317669 B...
Страница 27: ...Transducer arrays Figure 7 EM 122 blister and steel pipe arrangements example 317669 B 25...
Страница 42: ...EM 122 B B B Plastic TX protection window 40 317669 B...
Страница 46: ...EM 122 Figure 10 EM 122 Transceiver unit mounting 44 317669 B...
Страница 52: ...EM 122 Figure 13 Rear view 50 317669 B...
Страница 54: ...EM 122 Figure 15 Preamplifier Unit mounting 687 52 317669 B...
Страница 60: ...EM 122 Figure 18 Remote Control Junction Box outline dimensions 58 317669 B...
Страница 85: ...Cable layout and interconnections Figure 32 Transceiver Unit sub racks rear view 317669 B 83...
Страница 88: ...EM 122 Figure 34 Preamplifier underneath view 86 317669 B...
Страница 97: ...Cable layout and interconnections Figure 40 EM 122 Transceiver Unit s rear panel RX 317669 B 95...
Страница 126: ...EM 122 Figure 57 Cable layout 0 5 degree TX page 1 of 2 Cd021 106 Page 1 of 2 315396 Pro03 124 317669 B...
Страница 127: ...Drawing file Figure 58 Cable layout 0 5 degree TX page 2 of 2 Cd021 106 Page 2 of 2 315396 Pro03 317669 B 125...
Страница 128: ...EM 122 Ice window Figure 59 TX Ice window 126 317669 B...
Страница 129: ...Drawing file Figure 60 RX Ice window 317669 B 127...
Страница 131: ...Drawing file Preamplifier Unit Figure 62 RX Preamplifier Unit internal cabling 317669 B 129...
Страница 132: ...EM 122 Figure 63 RX Preamplifier Unit internal cabling 130 317669 B...
Страница 154: ...2013 Kongsberg Maritime...