22
426351/A
Context
To set
TTC POWER
use left/right arrows to choose power level and tap
SET
to confirm
your selection.
Procedure
1
Connect the test transducer cable to the upper right connector.
2
Place the Test transducer face to face with the transponder.
3
Communication between the TTC and the transponder may easily be tested by
selecting the
ACOUSTIC TEST
tab.
4
Enter serial number.
5
Enter the transponder channel number.
6
Tap
INTERROGATE
.
7
A green indicator will blink on the display if there is acoustic contact with the
transponder.
8
Tap
INTERROGATE
again to stop the
ACOUSTIC TEST
.
Configuring the transponder
This will leave your transponder with a new configuration.
Prerequisites
The transponder must be connected to the Transponder Test and Configuration unit
via a TTC Test and configuration cable.
Procedure
1
Tap
Transponder Configuration
.
2
Make changes to the configuration in the relevant fields.
3
Tap
DOWNLOAD A NEW CONFIGURATION
to update the transponder.
Result
If the configuration is successful you will receive a message; Downloaded new
configuration succeeded and reset performed sucessfully.
If the configuration is not successful you will receive a warning message; Download
config failed. Check all cables and try again.
Further requirements
See the Instruction manual for the Transducer Test and Configuration unit, document
number 350839, for more information.
cNODE Micro Instruction Manual
Содержание cNODE Micro
Страница 1: ...Instruction Manual cNODE Micro ...
Страница 2: ......
Страница 3: ...426351 A January 2018 Kongsberg Maritime AS cNODE Micro Transponder Instruction Manual ...
Страница 41: ...426351 A 39 Micro 31 180 outline drawing Drawing 424722 Drawing file ...
Страница 55: ......
Страница 56: ... 2018 Kongsberg Maritime ...