Kongsberg cJoy OT
The consumed power for each connect-switchboard is shown
in graphical form as a percentage of available power for each
connect-switchboard.
The number of bargraphs shown will be automatically adjusted
to reflect the vessel's current connect-switchboard configuration,
i.e. when it changes due to bus-tie breakers being opened/closed.
Each bargraph has a blue bar and two predefined power
consumption limits (one for warning and one for alarm) that are
shown as dashed horizontal lines. If the lower (warning) limit
(typically 60%) is exceeded the colour of the frame around the
bar changes to yellow. If the upper (alarm) limit (typically 80%)
is exceeded the colour of the frame around the bar changes to red.
The consumed power for a switchboard group.
The switchboards that are included in each connect-switchboard
(
Conn-swbd 1
,
Conn-swbd 2
,
Conn-swbd 3
, etc.) are designated
SwbdA
,
SwbdB
,
SwbdC
, etc.
The available power for a switchboard group.
Input dialogs
Input dialogs enable you to setup the system by changing parameter values and options.
Note
The operator terminal must be in command of the system before parameter values and
options can be changed.
Available input dialogs
The following input dialogs are provided:
• General Setup
• Sensors
• Thruster Setup
• Alarm Limits
• Pilot Setup (option)
• Heading Setpoint pop-up
40
385585/C