3.7 Troubleshooting
Operation
3-170
WA470-6H – VEAM946100
Removal and installation of battery
1. Before removing battery, remove the ground cable (normally
connected to the negetive (-) terminal). If any tool touches
between the positive terminal and the chassis, there is dan-
ger of sparks being generated. Loosen the nuts of terminal
and remove the wires from the battery.
2. After installing the battery, fix it with the battery fitting
securely.
Tightening torque: 2 to 2.9 Nm
3. When installing the battery, connect the ground cable last.
Insert the hole of the terminal on the battery and tighten the
nut.
REMARK
Tightening torque: 5.9 to 9.8 Nm
The batteries are on both sides at the rear of the machine. The
battery used for the ground is on the left side of the machine.
Precautions for charging battery
When charging the battery, if the battery is not handled correctly,
there is danger that the battery may explode. Always follow the
instructions in "Battery (3-157)" and the instruction manual
accompanying the charger, and do as follows.
!
Do not use or charge the battery if the battery electrolyte
level is below the LOWER LEVEL line. This may cause an
explosion. Always check the battery electrolyte level periodi-
cally and add distilled water to bring the electrolyte level to
the UPPER LEVEL line.
!
Set the voltage of the charger to match the voltage of the
battery to be charged. If the voltage is not selected correctly,
the charger may overheat and cause an explosion.
!
Connect the positive (+) charger clip of the charger to the
positive (+) terminal of the battery, then connect the negative
(-) charger clip of the charger to the negative (-) terminal of
the battery. Be sure to fix the clips securely.
!
Set the charging current to 1/10 of the value of the rated bat-
tery capacity; when carrying out rapid charging, set it to less
than the rated battery capacity.
If the charger current is too high, the electrolyte will leak or
dry up, and this may cause the battery to catch fire and
explode.
!
If the battery electrolyte is frozen, do not charge the battery
or start the engine with a different power source. There is a
hazard that this will ignite the battery electrolyte and cause
the battery to explode.
GK032230
Содержание WA470-6 2006
Страница 2: ......
Страница 3: ...Foreword WA470 6H VEAM946100 1 1 1 Foreword...
Страница 22: ...1 5 Contents Foreword 1 20 WA470 6H VEAM946100 7 Index 7 1 7 1 Index 7 2 8 Notes 8 1...
Страница 28: ...1 7 CE Conforming equipment Foreword 1 26 WA470 6H VEAM946100...
Страница 250: ...3 7 Troubleshooting Operation 3 178 WA470 6H VEAM946100...
Страница 340: ...4 9 Service procedure Every 12000 hours service Maintenance 4 90 WA470 6H VEAM946100...
Страница 341: ...Technical Data WA470 6H VEAM946100 5 1 5 Technical Data...
Страница 343: ...Technical Data 5 1 Technical data WA470 6H VEAM946100 5 3 GK032301 A B H I G C E F D...
Страница 348: ...5 4 Limit values for slopes Technical Data 5 8 WA470 6H VEAM946100...
Страница 381: ...Index WA470 6H VEAM946100 7 1 7 Index...
Страница 387: ...Notes WA470 6H VEAM946100 8 1 8 Notes...
Страница 388: ...Notes 8 2 WA470 6H VEAM946100...
Страница 389: ...Notes WA470 6H VEAM946100 8 3...
Страница 390: ...Notes 8 4 WA470 6H VEAM946100...
Страница 391: ...Notes WA470 6H VEAM946100 8 5...
Страница 392: ...Notes 8 6 WA470 6H VEAM946100...