MAINTENANCE
SERVICE PROCEDURE
PW160-7H VEAM390100
267
DRAIN ENGINE BREATHER OIL CATCHER
Periodically drain oil from the engine breather catcher and when-
ever it is necessary to remove the engine undercover.
1.
Remove undercover (1) and allow oil to drain out.
2.
Remove plug (2).
Replace undercover (1).
REMARK
Drain oil at every 500 hour service.
CHECK BEFORE STARTING
CHECK COOLANT LEVEL, ADD WATER
WARNING
Do not open the radiator cap unless necessary. When check-
ing the coolant, always check the radiator reserve tank when
the engine is cold.
1.
Open the rear door on the left side of the machine and check
that the cooling water level is between the FULL and LOW
marks on radiator reserve tank (1) (shown in the diagram on
the right).
If the water level is low, add water through the water filler of
reserve tank (1) to the FULL level.
2.
After adding water, tighten the cap securely.
3.
If the reserve becomes empty, first inspect for water leaks
and then fill the radiator and the reserve tank with water.
1
2
FULL
LOW
Содержание PW160-7H
Страница 2: ......
Страница 3: ...PW160 7H VEAM390100 3 FOREWORD ...
Страница 12: ...LOCATIONS OF PLATES TABLE TO ENTER SERIAL NO AND DISTRIBUTOR FOREWORD 12 PW160 7H VEAM390100 ...
Страница 18: ...18 PW160 7H VEAM390100 ...
Страница 220: ...TROUBLESHOOTING OPERATION 220 PW160 7H VEAM390100 ...
Страница 305: ...PW160 7H VEAM390100 305 SPECIFICATIONS ...
Страница 307: ...SPECIFICATIONS SPECIFICATIONS PW160 7H VEAM390100 307 1 PIECE BOOM ...
Страница 308: ...SPECIFICATIONS SPECIFICATIONS 308 PW160 7H VEAM390100 2 PIECE BOOM ...
Страница 345: ......
Страница 346: ...PW160 7H WHEELED EXCAVATOR Form No VEAM390100 2006 Komatsu Hanomag GmbH All Rights Reserved Printed in Germany 03 06 ...