SERVICE PROCEDURE
MAINTENANCE
266
PW160-7H VEAM390100
CHECK AND ADJUST AIR CONDITIONER
CHECK LEVEL OF REFRIGERANT (GAS)
WARNING
If the refrigerant used in the cooler gets into your eyes or on
your hands, it may cause loss of sight or frostbite. Do not
touch the refrigerant. Never loosen any part of the refrigerant
circuit.
Do not bring any flame close to any point where the refriger-
ant gas is leaking.
If there is a lack of refrigerant (Freon 134a), the cooling perfor-
mance will be poor.
When operating the cooler at high speed, there should be no bub-
bles in the sight glass (inspection window) mounted on the con-
denser unit receiver.
●
A: No bubbles in refrigerant flow: Correct
●
B: Bubbles in refrigerant flow (bubbles continuously pass
through): Refrigerant level low
●
C: Colorless, transparent: No refrigerant
REMARK
When there are bubbles, the refrigerant gas level is low, so
contact your refrigerant dealer to have refrigerant added. If the air
conditioner is run with the refrigerant gas level low, it will cause
damage to the compressor.
Check in off-season
When not being used for a long period, operate the cooler for 3 to
5 minutes once a month to supply lubricant to each component of
the compressor.
Inspection and maintenance items list for cooler
Sight glass
Receiver
A
B
C
Inspection and
maintenance items
Contents
Maintenance interval
Refrigerant (gas)
Filling quantity
Twice a year; spring and
autumn
Condenser
Clogging of fin
Every 500 hours
Compressor
Function
Every 4000 hours
V belt
Damage and tension
Every 250 hours
Blower motor and fan
Function (Check for abnormal sound)
When required
Control mechanism
Function (Check for normal function)
When required
Piping for connection
Installation condition looseness of tightening
connection portions gas leakage, damage
When required
Содержание PW160-7H
Страница 2: ......
Страница 3: ...PW160 7H VEAM390100 3 FOREWORD ...
Страница 12: ...LOCATIONS OF PLATES TABLE TO ENTER SERIAL NO AND DISTRIBUTOR FOREWORD 12 PW160 7H VEAM390100 ...
Страница 18: ...18 PW160 7H VEAM390100 ...
Страница 220: ...TROUBLESHOOTING OPERATION 220 PW160 7H VEAM390100 ...
Страница 305: ...PW160 7H VEAM390100 305 SPECIFICATIONS ...
Страница 307: ...SPECIFICATIONS SPECIFICATIONS PW160 7H VEAM390100 307 1 PIECE BOOM ...
Страница 308: ...SPECIFICATIONS SPECIFICATIONS 308 PW160 7H VEAM390100 2 PIECE BOOM ...
Страница 345: ......
Страница 346: ...PW160 7H WHEELED EXCAVATOR Form No VEAM390100 2006 Komatsu Hanomag GmbH All Rights Reserved Printed in Germany 03 06 ...