AMBIENT TEMPERATURE RANGE FOR OPERATION AND STORAGE
• The recommended ambient temperature range for operation and storage is -20 to +45 °C.
• When operating in ambient below 0 °C, refer to “COLD WEATHER OPERATION (3-252)” for details of pre-
cautions.
METHOD FOR OPERATIONS AND CHECKS AFTER STARTING ENGINE
k
k
WARNING
• If there has been any emergency stop, abnormal ac-
tuation or trouble, turn the starting switch key to OFF
position.
• Do not perform operations nor operate the levers or
pedal abruptly while the hydraulic oil is at low temper-
ature. Always perform the warm-up operation for the
hydraulic equipment until the hydraulic oil tempera-
ture caution lamp displays the correct temperature.
When the hydraulic oil temperature is low, the low
temperature display shown in the figure is given.
• Display (A) when temperature is correct: Caution
lamp background (C) is blue.
• Display (B) when temperature is low: Caution lamp
background (C) is white.
• If the warm-up operation for the hydraulic equipment
is not performed thoroughly, and the machine is
moved, the reaction of the machine to the operation of
the control levers and pedals will be slow and the
movement of the machine may not be what the opera-
tor intended. Particularly in a cold weather, be sure the
warm-up operation is completed.
• Keep away from the exhaust pipe while the engine is
running and immediately after stopping the engine.
Keep combustible materials away from the exhaust
pipe outlet.
There are 2 types of warm-up operation: warm-up of the engine and warm-up of the hydraulic equipment. In
addition, depending on the environment, the method of performing the warm-up operation may differ, so perform
the warm-up operation according to the descriptions given in the appropriate section.
The hydraulic equipment is not warmed by simply performing engine warm-up operation. Perform the warm-up
operations for the hydraulic equipment and engine separately. Warm-up of the hydraulic equipment thoroughly
ensures that the hydraulic oil is warmed up and that warm hydraulic oil circulates in all the control circuits.
METHOD FOR CHECKING STARTING CONDITION AND UNUSUAL NOISE OF
ENGINE
• When starting the engine, check that the engine causes no abnormal noise and that it starts up easily and
smoothly.
• Check that there is no abnormal noise when the engine is idling or when the engine speed rises slightly.
When there is an abnormal noise at the engine startup and if that condition continues, the engine may be dam-
aged. In that case, ask your Komatsu distributor to check the engine as soon as possible.
MACHINE OPERATIONS AND CONTROLS
OPERATION
3-176
Содержание PC490-11
Страница 2: ......
Страница 25: ...LOCATION OF SAFETY LABELS a b c d e f g h KS000848 T T SAFETY SAFETY LABELS 2 5...
Страница 48: ...Map with mirror and rear view camera visibility aids fitted PRECAUTIONS FOR OPERATION SAFETY 2 28...
Страница 72: ......
Страница 73: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1...
Страница 340: ......
Страница 341: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1...
Страница 421: ...SPECIFICATIONS 5 1...
Страница 425: ...6 7m Boom PC490 11 SPECIFICATIONS SPECIFICATIONS 5 5...
Страница 426: ...6 7m Boom PC490LC 11 SPECIFICATIONS SPECIFICATIONS 5 6...
Страница 428: ...7 1m Boom PC490 11 SPECIFICATIONS SPECIFICATIONS 5 8...
Страница 429: ...7 1m Boom PC490LC 11 SPECIFICATIONS SPECIFICATIONS 5 9...
Страница 430: ......
Страница 474: ......
Страница 475: ...REPLACEMENT PARTS 7 1...
Страница 491: ......
Страница 492: ...PC490 11 PC490LC 11 HYDRAULIC EXCAVATOR Form No UENAM01105 2016 KOMATSU All Rights Reserved Printed in Belgium 11 2016...