STORE OIL AND FUEL
• Keep oil and fuel indoors to prevent any water, dirt, or other impurities from getting in.
• When keeping drum cans for a long period, lay the drums so that the filler ports of the drums are located in
the lower part of the side to prevent moisture from being sucked in. If drums have to be stored outside, cov-
er them with a waterproof sheet or take other measures to protect them.
• To prevent any change in quality during long-term storage, be sure to use in the order of first in - first out
(use the oldest oil or fuel first).
FILTER
• Filters are extremely important safety parts. They prevent impurities in the oil, fuel, and air circuits from en-
tering important equipment and causing problems. Replace all filters periodically. For details, see Operation
and Maintenance Manual.
However, when working in severe conditions, replace the filters at shorter intervals according to the oil and
fuel (sulfur content) being used.
• Never try to clean and use again the filters (cartridge type). Always replace them with new filters.
• When replacing oil filters, check if any metal particles are attached to the old filters.
If any metal particles are found, consult your Komatsu distributor.
• Do not open packages of spare filters until just before they are to be used.
• Komatsu recommends using Komatsu genuine filters.
HANDLE ELECTRICAL COMPONENTS
k
k
WARNING
• When the battery disconnect switch key (if equipped) is turned to OFF position for the maintenance
work, always pull out the key and keep it with you.
If the key is left in the switch, someone may turn on the power by mistake. It is dangerous that caus-
es an electric shock.
• It is extremely dangerous if the electrical component becomes wet or the covering of the wiring is
damaged. This will cause an electrical leakage and may lead to malfunction of the machine.
Do not wash the inside of the operator's compartment with water.
When washing the machine, be careful not to let water get into the electrical components.
• When removing the connectors of electrical components after washing the machine or in the rain, wipe off
the water drop stuck around connectors before removing the connectors and keep the water drop away
from inside of the connectors.
• Checking and maintenance items are checking fan belt tension, checking damage of the fan belt and
checking battery fluid level.
• Komatsu recommends installing electric components specified by Komatsu.
• External electro-magnetic interference may cause malfunction of the control system controller. Accordingly,
consult your Komatsu distributor before installing a radio receiver or other wireless equipment to the ma-
chine.
• When working at the seashore, keep the electrical component clean to prevent corrosion.
• When installing electrical component, connect it to the special power supply connector.
Do not connect the optional power supply to the fuse or starting switch or battery relay, etc.
MAINTENANCE
OUTLINE OF MAINTENANCE
4-9
Содержание PC45MR-30403
Страница 61: ......
Страница 62: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1...
Страница 64: ...14 Engine rear cover 15 Cooling cover 16 Battery 17 KDPF OPERATION GENERAL VIEW 3 3...
Страница 310: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1...
Страница 411: ......
Страница 412: ...SPECIFICATIONS 5 1...
Страница 417: ......
Страница 459: ......
Страница 460: ...REPLACEMENT PARTS 7 1...
Страница 475: ...PC45MR 5 PC55MR 5 HYDRAULIC EXCAVATOR Form No TEN00763 04 2018 KOMATSU All Rights Reserved Printed in Japan 02 2018...